Set the parameters according to the operating conditions. The following list indicates purpose of use and
corresponding parameters.
Appendix 1 List of parameters classified by purpose of use
Purpose of Use
Parameter Number
Adjust the output torque of
the motor (current)
Manual torque boost
Pr. 0, Pr. 46
Simple magnetic flux vector control
Pr. 80, Pr. 90
Slip compensation
Pr. 245 to Pr. 247
Stall prevention operation
Pr. 22, Pr. 23, Pr. 48, Pr. 49, Pr. 66, Pr.
148, Pr. 149, Pr. 154, Pr. 156, Pr. 157
Multiple rating setting
Pr. 570
Limit the output frequency
Maximum/minimum frequency
Pr. 1, Pr. 2, Pr. 18
Avoid mechanical resonance points (frequency jump)
Pr. 31 to Pr. 36
Set V/F pattern
Base frequency, voltage
Pr. 3, Pr. 19, Pr. 47
V/F pattern matching applications
Pr. 14
Adjustable 5 points V/F
Pr. 71, Pr. 100 to Pr. 109
Frequency setting with
terminals (contact input)
Multi-speed setting operation
Pr. 4 to Pr. 6, Pr. 24 to Pr. 27,
Pr. 232 to Pr. 239
Jog operation
Pr. 15, Pr. 16
Input compensation of multi-speed and remote setting
Pr. 28
Remote setting function
Pr. 59
Acceleration/deceleration
time/pattern adjustment
Acceleration/deceleration time setting
Pr. 7, Pr. 8, Pr. 20, Pr. 21, Pr. 44, Pr. 45
Starting frequency
Pr. 13, Pr. 571
Acceleration/ deceleration pattern and back lash measures
Pr. 29, Pr. 140 to Pr. 143
Regeneration avoidance functions at deceleration
Pr. 882 to Pr. 886
Selection and protection of a
motor
Motor protection from overheat (electronic thermal relay
function)
Pr. 9, Pr. 51
Use the constant torque motor (applied motor)
Pr. 71
Motor brake and stop
operation
DC injection brake
Pr. 10 to Pr. 12
Selection of regeneration unit
Pr. 30, Pr. 70
Selection of motor stopping method
Pr. 250
Decelerate the motor to a stop at instantaneous power failure
Pr. 261 to Pr. 266
Function assignment of
external terminal and control
Function assignment of input terminal
Pr. 178 to Pr. 189
Start signal selection
Pr. 250
Logic selection of output stop signal (MRS)
Pr. 17
Selection of action conditions of the second function signal (RT)
Pr. 155
Terminal assignment of output terminal
Pr. 190 to Pr. 196
Detection of output frequency (SU, FU, FU2 signal)
Pr. 41 to Pr. 43, Pr. 50
Detection of output current (Y12 signal)
Detection of zero current (Y13 signal)
Pr. 150 to Pr. 153, Pr. 166,
Pr. 167
Remote output function (REM signal)
Pr. 495 to Pr. 497
Monitor display and monitor
output signal
Speed display and speed setting
Pr. 37, Pr. 144
Change of DU/PU monitor descriptions
Cumulative monitor clear
Pr. 52, Pr. 170, Pr. 171, Pr. 563, Pr.
564, Pr. 891
Change of the monitor output from terminal CA and AM
Pr. 54 to Pr. 56, Pr. 158, Pr. 867, Pr. 869
Adjustment of terminal CA and AM (calibration)
C0 (Pr. 900), C1 (Pr. 901)
Energy saving monitor
Pr. 891 to Pr. 899
Detection of output
frequencyand current
Detection of output frequency (SU, FU, FU2 signal)
Pr. 41 to Pr. 43, Pr. 50
Detection of output current (Y12 signal)
Detection of zero current (Y13 signal)
Pr. 150 to Pr. 153, Pr. 166,
Pr. 167