INVERTER SETTING
z
Parameters whose functions are always the same
When the FR-A7NF is mounted to the inverter, following parameter functions are always the same.
(Changed setting is invalid even if the setting value is changed.)
Parameter
Number
Name
Setting
Refer
to Page
Function
79
Operation mode selection
0
Network operation mode
7
PU operation interlock
180
RL terminal function selection
0
Low-speed operation command
— *2
181
RM terminal function selection
1
Middle-speed operation command
— *2
182
RH terminal function selection
2
High-speed operation command
— *2
183
RT terminal function selection
3
Second function selection
— *2
184
AU terminal function selection
9999
— (no function)
— *2
185
JOG terminal function selection
9999
— (no function)
— *2
186
CS terminal function selection
9999
— (no function)
— *2
187
MRS terminal function selection
24
Output stop
— *2
188
STOP terminal function selection
9999
— (no function)
— *2
189
RES terminal function selection
65
PU/NET operation switchover
— *2
12
PU operation interlock
— *2
190
RUN terminal function selection
0
Inverter running
— *2
191
SU terminal function selection
1
Up to frequency
— *2
192
IPF terminal function selection
2
Instantaneous power failure/undervoltage
— *2
193
OL terminal function selection
3
Overload alarm
— *2
194
FU terminal function selection
4
Output frequency detection
— *2
195
ABC1 terminal function selection
99
Fault output
— *2
196
ABC2 terminal function selection
9999
— (no function)
— *2
338
Communication operation
command source
0
Operation command source communication
339
Communication speed command
source
0
Speed command source communication