74
Parameter list
Differ according to capacities. (55K or lower/75K or higher)
Differs according to the voltage class. (200V class/400V class)
Parameters which can be set when the plug-in option (FR-A7NC) is mounted.
The setting is applied after converter reset or at the next power-ON.
"L.ERR" LED on FR-A7NC flickers when a setting is changed. If the converter is reset, the setting is applied and LED turns off.
The parameter number in parentheses is the one for use with the parameter unit (FR-PU07).
56
Current monitoring reference
0 to 500A/0 to 3600A
0.01A/
Rated
current
57
Restart selection
0, 9999
1
9999
58
Free parameter 1
0 to 9999
1
9999
59
Free parameter 2
0 to 9999
1
9999
61
Key lock operation selection
0, 10
1
0
65
Retry selection
0, 1, 2, 3, 4
1
0
67
Number of retries at fault occurrence
0 to 10, 101 to 110
1
0
68
Retry waiting time
0.1 to 360s
0.1s
1s
69
Retry count display erase
0
1
0
75
Reset selection/disconnected PU detection/
PU stop selection
0 to 3, 14 to 17
1
14
77
Parameter write selection
1, 2
1
2
80
Voltage control proportional gain
0 to 1000%
1%
100%
81
Voltage control integral gain
0 to 1000%
1%
100%
82
Current control proportional gain
0 to 200%
1%
100%
83
Current control integral gain
0 to 200%
1%
100%
117
PU communication station number
0 to 31
1
0
118
PU communication speed
48, 96, 192, 384
1
192
119
PU communication stop bit length
0, 1, 10, 11
1
1
120
PU communication parity check
0, 1, 2
1
2
121
Number of PU communication retries
0 to 10, 9999
1
1
123
PU communication waiting time setting
0 to 150ms, 9999
1ms
9999
124
PU communication CR/LF selection
0, 1, 2
1
1
145
PU display language selection
0 to 7
1
0
168
Parameter for manufacturer setting. Do not set.
169
269
342
Communication EEPROM write selection
0, 1
1
0
500
Communication error execution waiting time 0 to 999.8s
0.1s
0s
501
Communication error occurrence count
display
0
1
0
502
Stop mode selection at communication error 0, 3
1
0
542
Communication station number (CC-Link)
1 to 64
1
1
543
Baud rate (CC-Link)
0 to 4
1
0
,
CC-Link extended setting
0, 1, 12
1
0
C0(900)
FM terminal calibration
C1(901)
AM terminal calibration
989
Parameter copy alarm release
10/100
1
10/100
990
PU buzzer control
0, 1
1
1
991
PU contrast adjustment
0 to 63
1
58
Pr. CL
Parameter clear
0, 1
1
0
ALLC
All parameter clear
0, 1
1
0
Er.CL
Fault history clear
0, 1
1
0
PCPY
Parameter copy
0, 1, 2, 3
1
0
Parameter
Name
Range
Increments
Initial
value
Refer to
page
Customer
setting
HC2.book 74 ページ 2012年11月19日 月曜日 午前10時52分