188
These instruction codes are used to write or read parameters through the RS-485 communication and the CC-Link communication.
(Refer to
for the RS-485 communication
.
Refer to
for the CC-Link communication
.
)
"
" indicates valid and "
" indicates invalid of "parameter copy", "parameter clear", and "all parameter clear".
These parameters are not cleared by the parameter clear (all parameter clear) command, which are sent through RS-485 communication and CC-Link
communication. (Refer to
for the RS-485 communication
.
Refer to
page 109
for the CC-Link communication
.
)
Read and write of this parameter is enabled only when communicating through the PU connector.
Symbols in the table indicate parameters that function when the option is mounted.
...... FR-A7NC
Appendix 1 Instruction code list
Pr.
Name
Instruction
Code
Parameter
Re
ad
Wr
it
e
Ex
te
nde
d
Cop
y
Cl
ear
A
ll cl
ea
r
0
Simple mode selection
00 80
0
1
Maximum power supply frequency
01 81
0
2
Minimum power supply frequency
02 82
0
3
ROH terminal function selection
03 83
0
4
SOF terminal function selection
04 84
0
5
X1 terminal function selection
05 85
0
6
X2 terminal function selection
06 86
0
7
RES terminal function selection
07 87
0
8
SOF input selection
08 88
0
9
OH input selection
09 89
0
10
RDY signal logic selection
0A 8A
0
11
RSO terminal function selection
0B 8B
0
12
CVO terminal function selection
0C 8C
0
13
Y1 terminal function selection
0D 8D
0
14
Y2 terminal function selection
0E 8E
0
15
Y3 terminal function selection
0F 8F
0
16
ABC terminal function selection
10 90
0
22
Current limit level
16 96
0
23
Current limit level (regenerative)
17 97
0
24
OL signal output timer
18 98
0
25
Input current detection level
19 99
0
26
Input current detection signal delay time
1A 9A
0
27
Input current detection signal retention
time
1B 9B
0
28
Input current detection operation selection 1C 9C
0
29
Zero current detection level
1D 9D
0
30
Zero current detection time
1E 9E
0
31
Life alarm status display
1F 9F
0
32
Inrush current limit circuit life display
20 A0
0
33
Control circuit capacitor life display
21 A1
0
34
Maintenance timer
22 A2
0
35
Maintenance timer alarm output set time
23 A3
0
36
Cooling fan operation selection
24 A4
0
44
Instantaneous power failure detection
signal clear
2C AC 0
45
AM output filter
2D AD 0
46
Watt-hour meter clear
2E AE 0
47
Energization time carrying-over times
2F AF
0
48
Cumulative power monitor digit shifted
times
30 B0
0
49
Power supply frequency monitoring
reference
31 B1
0
50
AM terminal function selection
32 B2
0
51
Input power monitoring reference
33 B3
0
52
DU/PU main display data selection
34 B4
0
53
Input voltage monitoring reference
35 B5
0
54
FM terminal function selection
36 B6
0
55
Bus voltage monitoring reference
37 B7
0
56
Current monitoring reference
38 B8
0
57
Restart selection
39 B9
0
58
Free parameter 1
3A BA 0
59
Free parameter 2
3B BB 0
61
Key lock operation selection
3D BD 0
65
Retry selection
41 C1
0
67
Number of retries at fault occurrence
43 C3
0
68
Retry waiting time
44 C4
0
69
Retry count display erase
45 C5
0
75
Reset selection/disconnected PU
detection/PU stop selection
4B CB 0
Parameter write selection
4D CD 0
80
Voltage control proportional gain
50 D0
0
81
Voltage control integral gain
51 D1
0
82
Current control proportional gain
52 D2
0
83
Current control integral gain
53 D3
0
117 PU communication station number
11 91
1
118 PU communication speed
12 92
1
119 PU communication stop bit length
13 93
1
120 PU communication parity check
14 94
1
121 Number of PU communication retries
15 95
1
123 PU communication waiting time setting
17 97
1
124 PU communication CR/LF selection
18 98
1
145 PU display language selection
2D AD 1
269 Parameter for manufacturer setting. Do not set.
342 Communication EEPROM write selection
2A AA 3
500
Communication error execution waiting
time
00 80
5
501
Communication error occurrence count
display
01 81
5
502
Stop mode selection at communication
error
02 82
5
542
Communication station number (CC-Link)
2A AA 5
543 Baud rate (CC-Link)
2B AB 5
544 CC-Link extended setting
2C AC 5
C0
(900)
FM terminal calibration
5C DC 1
C1
(901)
AM terminal calibration
5D DD 1
989 Parameter copy alarm release
59 D9
9
990 PU buzzer control
5A DA 9
991 PU contrast adjustment
5B DB 9
Pr.
Name
Instruction
Code
Parameter
Re
ad
Wr
it
e
Ex
te
nde
d
Cop
y
Cl
ear
A
ll cl
ea
r
HC2.book 188 ページ 2012年11月19日 月曜日 午前10時52分