C o n f i g u r a t i o n a n d s o f t w a r e u t i l i t i e s
7/30 FT5000 HANDBOOK
SEL viewer menu options
The following menu options are available on the SEL viewer menu bar:
File
Open:
Allows you to view SEL data from a previously saved file if it was stored in binary
format. Selecting the Open Menu item lets you specify a filename under which the data
are found. The default filename is ‘SELLOG.DAT’. If the file cannot be opened, the
program displays an error message.
Close:
Closes the SEL viewer.
Save As:
Dumps the SEL data to a file in either binary raw or verbose text format. The
binary file can be retrieved later. Selecting this option lets you specify a filename to which
the data can be saved. The default filename is ‘SELLOG.DAT’. If no data exist, an error
message displays.
Exit:
Exits the EMP console.
Connect
View
SEL Information
: Displays SEL summary information.
All Events
: Displays all events in the SEL.
By Sensor Type
: Displays all events in the SEL generated by a specific sensor type,
e.g., voltage, temperature, etc.
By Event
: Displays all events in the SEL of a particular type, e.g., by memory or
threshold. A pop-up menu lets you select the event type to display. This menu displays all
event types that can be generated by the particular hardware.
Settings
: Lets you change several operating parameters for the SEL viewer. This menu
displays the following suboptions:
Display HEX/Verbose:
Toggles between HEX mode and interpreted mode of displaying
SEL records.
Output Text/Binary:
Specifies whether SEL data will be saved to the file in binary
format or verbose format.
Window
: Gives options for displaying currently open windows.
Help
: Provides version information for the SEL viewer and provides help topics on the
EMP console.
Sensor data record (SDR) viewer
The SDR viewer lets you view the records retrieved from the SDR repository. Options available
through the SDR viewer are:
View all SDR records
View SDR entries by SDR type
View SDR summary information
Set SDR display mode to either Hex or verbose mode
Close the SDR viewer
Exit the EMP console