A-4
FX Series PLC User's Manual - Data Communication Edition
Common Items
1 Introduction
1.2 Outline and Features of Communication Types
3) When the master station is an FX
2N
-16CCL-M
4) When the master station is an FX
3U
-16CCL-M
*1.
Local stations can not be connected.
2. Applicable PLCs
:Applicable (If applicable versions of main units are limited, they are described inside ( ).)
—:Not applicable
*2.
FX
3G
and FX
3GC
PLCs Ver. 2.00 or later, or FX
3U
and FX
3UC
PLCs Ver. 3.10 or later support the
access function to other FX Series PLC main units connected to FX
3U
-64CCL.
*3.
The table below shows versions of GX Works2 and GX Developer that support the access function to
other FX Series PLC main units via CC-Link.
PLC
FX
2
(FX),
FX
2C
FX
0N
FX
1S
FX
1N
FX
1NC
FX
2N
,
FX
2NC
FX
3S
FX
3G,
FX
3GC
FX
3U
,
FX
3UC
FX Series
master station
connectivity
FX
2N
-
16CCL-M
—
—
—
(Ver. 1.10
or later)
(Ver. 2.20
or later)
—
FX
3U
-
16CCL-M
—
—
—
—
—
—
—
*2
*2
(Ver. 2.20
or later)
FX Series
remote device station
connectivity
FX
2N
-
32CCL
—
—
—
FX Series
intelligent device
station connectivity
FX
3U
-
64CCL
—
—
—
—
—
—
—
*3
*3
(Ver. 2.20
or later)
PLC connected
through
PLC main unit accessed
FX
3G
FX
3GC
FX
3U
FX
3UC
GX Developer QCPU(Q mode)
Ver. 8.78G or later
—
Ver. 8.72A or later
Ver. 8.72A or later
GX Works2
QCPU(Q mode)
Ver. 1.08J or later Ver. 1.77F or later Ver. 1.08J or later
Ver. 1.08J or later
FXCPU
*2
+
FX
3U
-16CCL-M
Ver. 1.87R or later Ver. 1.87R or later Ver. 1.73B or later
Ver. 1.73B or later
Master station
FX
2N
-16CCL-M
Terminal resistor
FXCPU
FXCPU
Remote
device
station
Remote I/O
for CC-Link
Inverter,
AC servo, etc.
Sensor, solenoid valve,
etc.
Terminal resistor
•
Number of connectable units
•
Total extension distance
: Remote I/O station
: Remote device station
: 1200 m (3937' 0")
7 maximum
8 maximum
Master station
FX
3U
-16CCL-M
FXCPU
Terminal resistor
FXCPU
FXCPU
Intelligent
device
station
Remote
device
station
Terminal resistor
Remote I/O
for CC-Link
Inverter,
AC servo, etc.
Sensor, solenoid valve,
etc.
: Remote I/O station
: Remote device s Intelligent device station*
: 1200 m (3937' 0")
1
8 maximum
8 maximum
• Number of connectable units
• Total extension distance
Summary of Contents for FX-485ADP
Page 2: ......
Page 120: ...B 2 FX Series PLC User s Manual Data Communication Edition N N Network ...
Page 188: ...C 2 FX Series PLC User s Manual Data Communication Edition Parallel Link ...
Page 244: ...D 2 FX Series PLC User s Manual Data Communication Edition Computer Link ...
Page 344: ...E 2 FX Series PLC User s Manual Data Communication Edition Inverter Communication ...
Page 700: ...H 2 FX Series PLC User s Manual Data Communication Edition Programming Communication ...
Page 752: ...I 2 FX Series PLC User s Manual Data Communication Edition Remote Maintenance ...
Page 817: ......