FX Series PLC User's Manual - Data Communication Edition
Inverter Communication
6 Communication Setting in FX Programmable Controller
6.2 Communication Setting Using Parameter Method (GX Works2)
3
Setting the serial communication (parameters)
Set the parameters as shown below:
[1] Set the channel to be used. (This parameter can be set only in the FX
3G
,
FX
3GC
, FX
3U
and
FX
3UC
PLCs.)
[2] Check the "Operate Communication Setting" box.
[3] Set "Protocol" to "Non-procedural", "Data Length" to "7Bit", "Parity" to "Even", and "Stop Bit" to
"1Bit".
[4] Set "Transmission Speed" to either "4800", "9600", "19200" or "38400
*1
", and make sure that
the set value here is the same as the set value in the inverters.
[5] Ignore these items.
*1.
This transmission speed is supported only in FX
3S
, FX
3G
, FX
3GC
, FX
3U
and FX
3UC
PLC
S
.
Click [End].
4
Writing parameters and program to the PLC
Select [Online]
[Write to PLC] from the menu bar, click [Par Program], and then click
[Execute].
[1]
[2]
[3]
[5]
[4]
Summary of Contents for FX-485ADP
Page 2: ......
Page 120: ...B 2 FX Series PLC User s Manual Data Communication Edition N N Network ...
Page 188: ...C 2 FX Series PLC User s Manual Data Communication Edition Parallel Link ...
Page 244: ...D 2 FX Series PLC User s Manual Data Communication Edition Computer Link ...
Page 344: ...E 2 FX Series PLC User s Manual Data Communication Edition Inverter Communication ...
Page 700: ...H 2 FX Series PLC User s Manual Data Communication Edition Programming Communication ...
Page 752: ...I 2 FX Series PLC User s Manual Data Communication Edition Remote Maintenance ...
Page 817: ......