E-201
FX Series PLC User's Manual - Data Communication Edition
Inverter Communication
12 Related Data
12.5 FREQROL Inverter Parameter List
A
Comm
on I
te
ms
B
N:
N N
etwo
rk
C
Paral
le
l Li
nk
D
Com
puter Li
nk
E
In
verter
C
omm
uni
cation
F
N
on-Proto
col
C
ommunicati
on
(R
S/RS
2 Instru
ction
)
G
No
n-
Protoc
ol
Co
mmuni
ca
tion
(FX
2N
-2
32IF)
H
Programm
ing
Comm
uni
cation
I
Re
mo
te
Ma
intenance
Apx.A
D
isco
nti
nued
models
Pump function
589
A411
Auxiliary motor 3 stopping
frequency
590
A412
Auxiliary motor start detection time
591
A413
Auxiliary motor stop detection time
Traverse
function
592
A300
Traverse function selection
592
A300
Traverse function selection
593
A301
Maximum amplitude amount
593
A301
Maximum amplitude amount
594
A302
Amplitude compensation amount
during deceleration
594
A302
Amplitude compensation amount
during deceleration
595
A303
Amplitude compensation amount
during acceleration
595
A303
Amplitude compensation amount
during acceleration
596
A304
Amplitude acceleration time
596
A304
Amplitude acceleration time
597
A305
Amplitude deceleration time
597
A305
Amplitude deceleration time
598
H102
Undervoltage level
598
H102
Undervoltage level
599
T721
X10 terminal input selection
599
T721
X10 terminal input selection
Electronic
thermal O/L
relay
600
H001
First free thermal reduction
frequency 1
600
H001
First free thermal reduction
frequency 1
601
H002
First free thermal reduction ratio 1
601
H002
First free thermal reduction ratio 1
602
H003
First free thermal reduction
frequency 2
602
H003
First free thermal reduction
frequency 2
603
H004
First free thermal reduction ratio 2
603
H004
First free thermal reduction ratio 2
604
H005
First free thermal reduction
frequency 3
604
H005
First free thermal reduction
frequency 3
606
T722
Power failure stop external signal
input selection
606
T722
Power failure stop external signal
input selection
607
H006
Motor permissible load level
607
H006
Motor permissible load level
608
H016
Second motor permissible load
level
608
H016
Second motor permissible load level
PID control
609
A624
PID set point/deviation input
selection
609
A624
PID set point/deviation input
selection
610
A625
PID measured value input selection
610
A625
PID measured value input selection
611
F003
Acceleration time at a restart
611
F003
Acceleration time at a restart
Cumulative
pulse monitor
635
M610
Cumulative pulse clear signal
selection
636
M611
Cumulative pulse division scaling
factor
637
M612
Control terminal option—Cumulative
pulse division scaling factor
638
M613
Cumulative pulse storage
Brake sequence
function
639
A108
Brake opening current selection
640
A109
Brake operation frequency selection
641
A130
Second brake sequence operation
selection
642
A120
Second brake opening frequency
643
A121
Second brake opening current
644
A122
Second brake opening current
detection time
645
A123
Second brake operation time at start
646
A124
Second brake operation frequency
647
A125
Second brake operation time at stop
648
A126
Second deceleration detection
function selection
FREQROL F800 Series
FREQROL A800 Series
Function
Pr
No.
Pr
Group
Name
Pr
No.
Pr
Group
Name
Summary of Contents for FX-485ADP
Page 2: ......
Page 120: ...B 2 FX Series PLC User s Manual Data Communication Edition N N Network ...
Page 188: ...C 2 FX Series PLC User s Manual Data Communication Edition Parallel Link ...
Page 244: ...D 2 FX Series PLC User s Manual Data Communication Edition Computer Link ...
Page 344: ...E 2 FX Series PLC User s Manual Data Communication Edition Inverter Communication ...
Page 700: ...H 2 FX Series PLC User s Manual Data Communication Edition Programming Communication ...
Page 752: ...I 2 FX Series PLC User s Manual Data Communication Edition Remote Maintenance ...
Page 817: ......