How to Use RS2 Instruction
This section explains the function, operation and programming method of the RS2 instruction.
Available channels vary depending on the main unit.
For details, refer to Section 3.2.
1. Applicable devices
:
Only available for FX
3G
, FX
3GC
, FX
3U
and FX
3UC
PLCs.
m, n: 0 to 4096 points
n1:
K0, K1 or K2
2. Program example
Oper-
and
Type
Bit Devices
Word Devices
Others
System/User
Digit Specification
System/User
Special
Unit
Index
Con-
stant
Real
Number
Charac-
ter String
Pointer
X Y M T C S D
.b KnX KnY KnM KnS T C D R U
\G
V Z Modify K H
E
"
"
P
m
n
n1
S
D
M0
FNC 87
RS2
D100
D0
D200
D1
S
D
m
n
Head device storing send
data
Number of send data: 0 to
4096
Amount of received data: 0 to 4096 points
Head device storing receive data
K1
n1
Communication channel
K0: ch 0
K2: ch 2
K1: ch 1
Summary of Contents for FX-485ADP
Page 2: ......
Page 120: ...B 2 FX Series PLC User s Manual Data Communication Edition N N Network ...
Page 188: ...C 2 FX Series PLC User s Manual Data Communication Edition Parallel Link ...
Page 244: ...D 2 FX Series PLC User s Manual Data Communication Edition Computer Link ...
Page 344: ...E 2 FX Series PLC User s Manual Data Communication Edition Inverter Communication ...
Page 700: ...H 2 FX Series PLC User s Manual Data Communication Edition Programming Communication ...
Page 752: ...I 2 FX Series PLC User s Manual Data Communication Edition Remote Maintenance ...
Page 817: ......