I-9
FX Series PLC User's Manual - Data Communication Edition
Remote Maintenance
1 Outline
1.4 Programming Tool Applicability
A
Comm
on I
te
ms
B
N:
N N
etwo
rk
C
Paral
le
l Li
nk
D
Com
puter Li
nk
E
In
verter
C
omm
uni
cation
F
N
on-Proto
col
C
ommunicati
on
(R
S/RS
2 Instru
ction
)
G
No
n-
Protoc
ol
Co
mmuni
ca
tion
(FX
2N
-2
32IF)
H
Programm
ing
Comm
uni
cation
I
Re
mo
te
Ma
intenance
Apx.A
D
isco
nti
nued
models
In the case of non-applicable versions (setting an alternative model)
For FX
1S
, FX
2N
and FX
2NC
PLCs, it is not possible to create programs using programming tools of
inapplicable versions.
For FX
1N
, FX
1NC
, FX
3S
, FX
3G
, FX
3GC
, FX
3U
and FX
3UC
PLCs of the following versions, it is possible to create
programs by setting an alternative model. In this case, however, created programs are limited to the function
range (such as instructions and program size) supported by the selected alternative model.
Any programming tool not shown below is not applicable.
1. English versions
*1.
An alternative model can be set in GX Developer SW2 A to Ver. 8.18U.
*2.
An alternative model can be set in GX Developer SW2 A to Ver. 8.72A.
*3.
Select "FX
2N
" in model selection when "FX
1N
" is not supported.
*4.
An alternative model can be set in GX Developer SW2 A to SW5 A.
Model to be
programmed
Product name
(Model name is shown
below.)
Version allowing
setting of alternative
model
Setting an
alternative
model
Remarks
FX
3U
, FX
3UC
Series
GX Developer
SW
D5C(F)-GPPW-E
SW2 A or later
*1
FX
2N
The PP modem mode (ch1) and
PP modem mode (ch2) cannot be
set.
FX-PCS/WIN-E
SW0PC-FXGP/WIN-E
Ver. 1.00 or later
FX
3G
, FX
3GC
Series
GX Works2
SW
DNC-GXW2-E
Ver. 1.64S or later
FX
3G
GX Developer
SW
D5C(F)-GPPW-E
SW2 A or later
*2
FX
1N*3
The PP modem mode (ch1) and
PP modem mode (ch2) cannot be
set.
FX-PCS/WIN-E
SW0PC-FXGP/WIN-E
Ver. 1.00 or later
FX
3S
Series
GX Works2
SW
DNC-GXW2-E
Ver. 1.08J or later
FX
3G
GX Developer
SW
D5C(F)-GPPW-E
Ver. 8.72A or later
GX Developer
SW
D5C(F)-GPPW-E
SW2 A or later
*2
FX
1N*3
The PP modem mode (ch1)
cannot be set.
FX-PCS/WIN-E
SW0PC-FXGP/WIN-E
Ver. 1.00 or later
FX
1N
, FX
1NC
Series
GX Developer
SW
D5C(F)-GPPW-E
SW2 A or later
*4
FX
2N
FX-PCS/WIN-E
SW0PC-FXGP/WIN-E
Ver. 1.00 or later
Summary of Contents for FX-485ADP
Page 2: ......
Page 120: ...B 2 FX Series PLC User s Manual Data Communication Edition N N Network ...
Page 188: ...C 2 FX Series PLC User s Manual Data Communication Edition Parallel Link ...
Page 244: ...D 2 FX Series PLC User s Manual Data Communication Edition Computer Link ...
Page 344: ...E 2 FX Series PLC User s Manual Data Communication Edition Inverter Communication ...
Page 700: ...H 2 FX Series PLC User s Manual Data Communication Edition Programming Communication ...
Page 752: ...I 2 FX Series PLC User s Manual Data Communication Edition Remote Maintenance ...
Page 817: ......