I-28
FX Series PLC User's Manual - Data Communication Edition
Remote Maintenance
5 How to Setup Modems on the PLC Side
5.1 Setting Using GX Works2
*1.
When an FX
3S
, FX
3G
, FX
3GC
, FX
3U
and FX
3UC
PLC is used
*2.
When an FX
3G
, FX
3GC
, FX
3U
and FX
3UC
PLC is used
3
Setting the AT command for the unregistered modem
When "User Register Mode", "PP Modem Mode (CH1)", or "PP Modem Mode (CH2)" is selected in
"MODEM Initialized", the AT command setting is required. For the AT command setting method for
unregistered modems, refer to Subsection 5.1.3.
The AT command setting is not required when "AIWA[PV-AF288]" or "OMRON(ME3314B)" is
selected.
4
Writing the parameter and program to the PLC
Select [Online]
[Write to PLC] from the menu bar.
Click [Parameter]
[PLC Parameter/Network Parameter] in the project tree.
When the AT command is set for an unregistered modem, next put a check mark next to "Device
Memory"
"MAIN".
After placing the check mark, click the [Execute] button to write the contents to the FX PLC.
Set item
Description
Modem model
name
Manufacturer
None
Select this item when remote maintenance is
not used.
—
—
User Register Mode
Select this item when the modem to be used
is not registered.
Unregistered
modem
—
AIWA(PV-AF288)
Select the corresponding item when either
modem is to be used.
PV-AF288
AIWA CO., LTD.
OMRON(ME3314B)
ME3314B
OMRON
Corporation
PP Modem Mode (CH1)
*1
Select this item when the modem to be used
satisfying the PP modem mode specifications
is not registered.
Unregistered
modem
—
PP Modem Mode (CH2)
*2
Select this item when remote maintenance is
executed in ch2.
Unregistered
modem
—
Summary of Contents for FX-485ADP
Page 2: ......
Page 120: ...B 2 FX Series PLC User s Manual Data Communication Edition N N Network ...
Page 188: ...C 2 FX Series PLC User s Manual Data Communication Edition Parallel Link ...
Page 244: ...D 2 FX Series PLC User s Manual Data Communication Edition Computer Link ...
Page 344: ...E 2 FX Series PLC User s Manual Data Communication Edition Inverter Communication ...
Page 700: ...H 2 FX Series PLC User s Manual Data Communication Edition Programming Communication ...
Page 752: ...I 2 FX Series PLC User s Manual Data Communication Edition Remote Maintenance ...
Page 817: ......