Registering the AT command for the connected modem
Select "Modem at MELSOFT Application Side" in the project tree, and click the [New AT
Command] button.
Input "Title" and "AT Command", and click the [OK] button.
- Input a name easy to understand such as the modem model name to "Title".
- Input "AT Command" while referring to the description below.
1. In the case of a modem whose operation is confirmed
For such a modem, input the following AT command.
2. In the case of any other modem (whose operation is not confirmed)
Click the [Help of AT Command] button.
Refer to the contents of the help and the manual of the connected modem, create the AT command.
3. Contents of help for the AT command
The table below shows the contents of description about [Help of AT Command].
Setting example: AT&C1Q0V1\N3&D0&K0
Modem manufacturer name
Modem model
name
AT command set value
Remarks
I-O DATA DEVICE, INC.
DFML-560ER
AT&C1E0Q0S0=2&K0&D0
AIWA CO., LTD.
PV-BF5606
ATE0S0=2&K0&D0
OMRON Corporation
ME5614E
ATE0S0=2&K0&D0
Modem version: F/W Ver. 2.300
ME5614E2
OMRON Corporation
ME5614D
ATE0S0=2&K0&D0
Modem version: F/W Ver. 2.300
AT command
Description
AT&Cn
Set the mode in which the CD signal is set to ON when the carrier from the counterpart is received.
ATQn
Set the AT command so that the result code for the AT command is sent back.
ATVn
Set the AT command so that the response to the AT command is given in a character string.
AT\Nn
The MNP automatic selection mode is recommended.
When the MNP block size is a set item, "128 bytes maximum per block" is general.
When the MNP automatic selection mode cannot be specified, specify the direct mode in the
asynchronous communication mode.
AT&Dn
Set the ER signal to "normally ON".
AT&Kn (AT&Hn&In&Rn) Set "no flow control".
AT&Xn
When a converter is used, set "no dial tone".
It is not necessary to set this item when a converter is not used.
Summary of Contents for FX-485ADP
Page 2: ......
Page 120: ...B 2 FX Series PLC User s Manual Data Communication Edition N N Network ...
Page 188: ...C 2 FX Series PLC User s Manual Data Communication Edition Parallel Link ...
Page 244: ...D 2 FX Series PLC User s Manual Data Communication Edition Computer Link ...
Page 344: ...E 2 FX Series PLC User s Manual Data Communication Edition Inverter Communication ...
Page 700: ...H 2 FX Series PLC User s Manual Data Communication Edition Programming Communication ...
Page 752: ...I 2 FX Series PLC User s Manual Data Communication Edition Remote Maintenance ...
Page 817: ......