B-61
FX Series PLC User's Manual - Data Communication Edition
N:N Network
10 Related Data
10.2 Details of Related Devices
A
Comm
on I
te
ms
B
N:
N N
etwo
rk
C
Paral
le
l Li
nk
D
Com
puter Li
nk
E
In
verter
C
omm
uni
cation
F
N
on-Proto
col
C
ommunicati
on
(R
S/RS
2 Instru
ction
)
G
No
n-
Protoc
ol
Co
mmuni
ca
tion
(FX
2N
-2
32IF)
H
Programm
ing
Comm
uni
cation
I
Re
mo
te
Ma
intenance
Apx.A
D
isco
nti
nued
models
10.2.4 Data transfer sequence error [M8138 to M8190] [M504 to M511]
These devices turn ON when a data transfer sequence error occurs in the master station or a slave station.
1. Stations requiring program setting
Setting is required for the master station and slave stations.
However, setting for the station itself is not required.
2. Detailed contents
A used device varies depending on the FX Series.
3. Cautions on use
Data transfer sequence errors in a station itself cannot be detected.
Do not set these devices to ON using a program or programming tool.
10.2.5 Data transfer sequence ON [M8191] [M503]
This device remains ON while data transfer is being from or to in the master station or slave station.
1. Stations requiring program setting
Setting is required for the master station and slave stations.
2. Detailed contents
The device used varies depending on the FX Series.
3. Cautions on use
Do not set this device to ON using a program or programming tool.
10.2.6 Serial communication error code [D8063 and D8438]
These devices store the serial communication error code (D8438 is available in the FX
3G
, FX
3GC
, FX
3U
and
FX
3UC
).
1. Stations requiring program setting
Setting is required for the master station and slave stations to check the error code.
2. Detailed contents
The following error code is stored when a serial communication error occurs.
3. Cautions on use
Serial communication errors are not cleared even after communication has recovered its normal status.
Serial communication errors are cleared in FX
3S
, FX
3G
, FX
3GC
, FX
3U
and FX
3UC
PLCs when the power is
turned off and on.
Serial communication errors are cleared in other PLCs when the mode is switched from STOP to RUN.
FX Series
Master
station
Slave
station
No. 1
Slave
station
No. 2
Slave
station
No. 3
Slave
station
No. 4
Slave
station
No. 5
Slave
station
No. 6
Slave
station
No. 7
FX
1N
, FX
1NC
, FX
2N
,
FX
2NC
, FX
3S
,
FX
3G
,
FX
3GC
, FX
3U
, FX
3UC
M8183
M8184
M8185
M8186
M8187
M8188
M8189
M8190
FX
0N
, FX
1S
M504
M505
M506
M507
M508
M509
M510
M511
FX Series
Data transfer sequence ON
FX
1N
, FX
1NC
, FX
2N
,
FX
2NC
, FX
3S
,
FX
3G
,
FX
3GC
, FX
3U
, FX
3UC
M8191
FX
0N
, FX
1S
M503
Error code
Description
ch1
ch2
D8063
D8438
6308
3808
N:N Network parameter setting error
6309
3809
N:N Network setting error
Summary of Contents for FX-485ADP
Page 2: ......
Page 120: ...B 2 FX Series PLC User s Manual Data Communication Edition N N Network ...
Page 188: ...C 2 FX Series PLC User s Manual Data Communication Edition Parallel Link ...
Page 244: ...D 2 FX Series PLC User s Manual Data Communication Edition Computer Link ...
Page 344: ...E 2 FX Series PLC User s Manual Data Communication Edition Inverter Communication ...
Page 700: ...H 2 FX Series PLC User s Manual Data Communication Edition Programming Communication ...
Page 752: ...I 2 FX Series PLC User s Manual Data Communication Edition Remote Maintenance ...
Page 817: ......