D-94
FX Series PLC User's Manual - Data Communication Edition
Computer Link
9 Related Data
9.2 Details of Related Devices
2. Cautions on use
Error codes are not cleared even after communication recovers its normal status.
Serial communication errors are cleared in FX
3S
, FX
3G
, FX
3GC
, FX
3U
and FX
3UC
PLCs when the power is
turned off and on.
Serial communication errors are cleared in other PLCs when the mode is switched from STOP to RUN.
9.2.8
Communication format setting [D8120 and D8420]
These devices set the serial communication format.
1. Detailed contents
These devices set the serial communication format. In FX
1S
, FX
1N
, FX
1NC
, FX
2N
, FX
2NC
, FX
3S
, FX
3G
, FX
3GC
,
FX
3U
and FX
3UC
PLCs, the contents set in parameters are transferred to these devices when the power is
turned ON.
In FX
2
(FX), FX
2C
and FX
0N
PLCs, set the communication format using a sequence program, and then turn
ON the power.
In all PLCs except FX
3G
, FX
3GC
, FX
3U
and FX
3UC
PLCs using communication port ch1, use D8120.
Set the communication format using parameters when using the communication port ch2 in FX
3G
, FX
3GC
,
FX
3U
and FX
3UC
PLCs.
Use D8420 for confirmation.
The tables below show the setting details.
• Contents of D8120
*1.
This setting is available only in FX
3S
, FX
3G
, FX
3GC
, FX
3U
and FX
3UC
PLCs.
Bit No.
Name
Contents
0 (bit = OFF)
1 (bit = ON)
b0
Data length
7-bit
8-bit
b1
b2
Parity
b2, b1
(0, 0): Not provided
(0, 1): Odd
(1, 1): Even
b3
Stop bit
1-bit
2-bit
b4
b5
b6
b7
Baud rate
(bps)
b7, b6, b5, b4
b7, b6, b5, b4
(0, 0, 1, 1): 300
(0, 1, 1, 1): 4800
(0, 1, 0, 0): 600
(1, 0, 0, 0): 9600
(0, 1, 0, 1): 1200
(1, 0, 0, 1): 19200
(0, 1, 1, 0): 2400
(1, 0, 1, 0): 38400
*1
b8
Header
Not provided
Provided (D8124) Initial value: STX (02H)
b9
Terminator
Not provided
Provided (D8125) Initial value: ETX (03H)
b10
b11
Control line
Com-
puter
link
b11, b10
(0, 0): RS-485/RS-422 interface
(1, 0): RS-232C interface
b12
Not applicable
b13
Sum check
Not added
Added
b14
Protocol
Not used
Used
b15
Control
procedure
Format 1
Format 4
Summary of Contents for FX-485ADP
Page 2: ......
Page 120: ...B 2 FX Series PLC User s Manual Data Communication Edition N N Network ...
Page 188: ...C 2 FX Series PLC User s Manual Data Communication Edition Parallel Link ...
Page 244: ...D 2 FX Series PLC User s Manual Data Communication Edition Computer Link ...
Page 344: ...E 2 FX Series PLC User s Manual Data Communication Edition Inverter Communication ...
Page 700: ...H 2 FX Series PLC User s Manual Data Communication Edition Programming Communication ...
Page 752: ...I 2 FX Series PLC User s Manual Data Communication Edition Remote Maintenance ...
Page 817: ......