E-190
FX Series PLC User's Manual - Data Communication Edition
Inverter Communication
12 Related Data
12.5 FREQROL Inverter Parameter List
12.5.3 Parameters in F800 and A800 Series
The following parameters are provided in FREQROL inverters. Pr. No.1000 and later are not supported.
(For details, make sure to refer to the respective inverter manual.)
FREQROL F800 Series
FREQROL A800 Series
Function
Pr
No.
Pr
Group
Name
Pr
No.
Pr
Group
Name
Basic functions
0
G000
Torque boost
0
G000
Torque boost
1
H400
Maximum frequency
1
H400
Maximum frequency
2
H401
Minimum frequency
2
H401
Minimum frequency
3
G001
Base frequency
3
G001
Base frequency
4
D301
Multi-speed setting (high speed)
4
D301
Multi-speed setting (high speed)
5
D302
Multi-speed setting (middle speed)
5
D302
Multi-speed setting (middle speed)
6
D303
Multi-speed setting (low speed)
6
D303
Multi-speed setting (low speed)
7
F010
Acceleration time
7
F010
Acceleration time
8
F011
Deceleration time
8
F011
Deceleration time
9
H000
Electronic thermal O/L relay
9
H000
Electronic thermal O/L relay
C103
Rated motor current
C103
Rated motor current
DC injection
brake
10
G100
DC injection brake operation
frequency
10
G100
DC injection brake operation
frequency
11
G101
DC injection brake operation time
11
G101
DC injection brake operation time
12
G110
DC injection brake operation voltage
12
G110
DC injection brake operation voltage
13
F102
Starting frequency
13
F102
Starting frequency
14
G003
Load pattern selection
14
G003
Load pattern selection
Jog operation
15
D200
Jog frequency
15
D200
Jog frequency
16
F002
Jog acceleration/deceleration time
16
F002
Jog acceleration/deceleration time
17
T720
MRS input selection
17
T720
MRS input selection
18
H402
High speed maximum frequency
18
H402
High speed maximum frequency
-
19
G002
Base frequency voltage
19
G002
Base frequency voltage
Acceleration/
deceleration
times
20
F000
Acceleration/deceleration reference
frequency
20
F000
Acceleration/deceleration reference
frequency
21
F001
Acceleration/deceleration time
increments
21
F001
Acceleration/deceleration time
increments
Stall prevention
22
H500
Stall prevention operation level
22
H500
Stall prevention operation level
(Torque limit level)
23
H610
Stall prevention operation level
compensation factor at double
speed
23
H610
Stall prevention operation level
compensation factor at double
speed
Multi-speed
setting
24
D304
Multi-speed setting (4 speed)
24
D304
Multi-speed setting (4 speed)
25
D305
Multi-speed setting (5 speed)
25
D305
Multi-speed setting (5 speed)
26
D306
Multi-speed setting (6 speed)
26
D306
Multi-speed setting (6 speed)
27
D307
Multi-speed setting (7 speed)
27
D307
Multi-speed setting (7 speed)
28
D300
Multi-speed input compensation
selection
28
D300
Multi-speed input compensation
selection
29
F100
Acceleration/deceleration pattern
selection
29
F100
Acceleration/deceleration pattern
selection
30
E300
Regenerative function selection
30
E300
Regenerative function selection
Frequency jump
31
H420
Frequency jump 1A
31
H420
Frequency jump 1A
32
H421
Frequency jump 1B
32
H421
Frequency jump 1B
33
H422
Frequency jump 2A
33
H422
Frequency jump 2A
34
H423
Frequency jump 2B
34
H423
Frequency jump 2B
35
H424
Frequency jump 3A
35
H424
Frequency jump 3A
36
H425
Frequency jump 3B
36
H425
Frequency jump 3B
Summary of Contents for FX-485ADP
Page 2: ......
Page 120: ...B 2 FX Series PLC User s Manual Data Communication Edition N N Network ...
Page 188: ...C 2 FX Series PLC User s Manual Data Communication Edition Parallel Link ...
Page 244: ...D 2 FX Series PLC User s Manual Data Communication Edition Computer Link ...
Page 344: ...E 2 FX Series PLC User s Manual Data Communication Edition Inverter Communication ...
Page 700: ...H 2 FX Series PLC User s Manual Data Communication Edition Programming Communication ...
Page 752: ...I 2 FX Series PLC User s Manual Data Communication Edition Remote Maintenance ...
Page 817: ......