22.7 Personal Computer Side Setting
Step 6.
Click [Setting].
Set the connection destination of the GOT, [QJ71E71] or [QnUDE(H)], to [Type].
Step 7.
The settings are as follows.
• For [QJ71E71]
[Unit]: Specify the number assigned to the Ethernet module for [Network No.], [Station No.], and [IP
Address].
[GOT]: Specify the number assigned to the GOT for [Station No.].
• For [QnUDE(H)]
[Unit]: Specify the number assigned to QnUDE(H) for [IP Address].
Step 8.
After completing [Edit Project], be sure to connect the GOT with the robot controller and change to [Online]
for the operation mode.