2 - 40
2.3 MELSEC iQ-F
*1
Available for file register of block No. switched with the RSET instruction.
*2
Only the intelligent function module on the station connected to GOT can be specified.
Set within the address range of the buffer memory existing in the target intelligent function module.
*3
The device No. must be set in multiples of 16.
*4
Only reading is possible.
*5
Only writing is possible.
*6
Use the following devices to write data to the RAM of a servo amplifier.
• PA: 1 to 32
Word device
Data register (D)
D0 to D7999
Decimal
Special data register (SD)
SD0 to SD11999
Link register (W)
W0 to W7FFF
Hexadecimal
Timer (current value) (TN)
TN0 to TN1023
Decimal
Counter (current value)(CN)
CN0 to CN1023
Retentive timer (current value) (SN)
SN0 to SN1023
Link special register (SW)
SW0 to SW7FFF
Hexadecimal
Remote register (Ww)
*8
Ww0 to Ww1FFF
Remote register (Wr)
*8
Wr0 to Wr1FFF
File register (R)
*1
R0 to R32767
Decimal
Index register (16 bits) (Z)
Z0 to Z23
Buffer memory (Intelligent function module) (G)
*2
G0 to G262143
Basic parameter (PA)
*6*7*9
PA1 to PA32
PA1001 to PA1032
Gain filter parameter (PB)
*6*7*9
PB1 to PB64
PB1001 to PB1064
Extension setting parameter (PC)
*6*7*9
PC1 to PC64
PC1001 to PC1064
I/O setting parameter (PD)
*6*7*9
PD1 to PD48
PD1001 to PD1048
Linear servo motor/DD motor setting parameter (PL)
*6*7*9
PL1 to PL48
PL1001 to PL1048
Status display (ST)
*4*7*9
ST0 to ST48
Extension setting 2 parameter (PE)
*6*7*9
PE1 to PE64
PE1001 to PE1064
Extension setting 3 parameter (PF)
*6*7*9
PF1 to PF48
PF1001 to PF1048
Alarm (current alarm, extended for J4) (ALM)
*4*7*9
ALM0 to ALM1
ALM1 to ALM59
Alarm (alarm history, extended for J4) (ALM)
*4*7*9
ALM200 to ALM215
ALM220 to ALM235
ALM240 to ALM255
Machine diagnosis data (MD)
*4*7*9
MD0 to MD10
One-touch tuning data (OTS)
*4*7*9
OTS0 to OTS3
External input (DI)
*7*9
DI0 to DI6
External output (DO)
*4*7*9
DO0 to DO
The word specification of the bit device
*3
(except Timer, Counter, Retentive timer)
Setting range of each bit devices
-
Double word
device
Long counter (current value) (LCN)
*3
LCN0 to LCN1023
Decimal
Index register (32 bits) (LZ)
LZ0 to LZ11
Lifetime diagnosis (ALD)
*4*7*9
ALD0 to ALD1
Input signal for test operation (for test operation) (TMI)
*5*7*9
TMI0 to TMI2
Forced output of signal pin (for test operation) (TMO)
*5*7*9
TMO0
Set data (for test operation) (TMD)
*5*7*9
TMD0 to TMD1
TMD3
Device name
Setting range
Device No.
representation
Summary of Contents for GOT2000 Series
Page 2: ......
Page 84: ......
Page 432: ...6 58 6 6 Precautions ...
Page 578: ...9 54 9 6 Precautions ...
Page 726: ...12 84 12 5 Precautions ...
Page 756: ......
Page 822: ...14 66 14 4 Device Range that Can Be Set ...
Page 918: ...15 96 15 7 Precautions ...
Page 930: ...16 12 16 6 Precautions ...
Page 964: ......
Page 1002: ...19 38 19 7 Precautions ...
Page 1022: ...20 20 20 5 Precautions ...
Page 1023: ...MULTI CHANNEL FUNCTION 21 MULTI CHANNEL FUNCTION 21 1 ...
Page 1024: ......
Page 1054: ...21 30 21 5 Multi channel Function Check Sheet ...
Page 1055: ...FA TRANSPARENT FUNCTION 22 FA TRANSPARENT FUNCTION 22 1 ...
Page 1056: ......
Page 1223: ......