4 - 90
4.3 MELSEC Redundant Setting
*1 Pair number
Redundant CPU pair means the redundant CPUs (System A / System B) in the redundant system configuration.
Pair number is the number assigned to each redundant CPU pair.
Example: Ethernet connection in the RCPU redundant system (Pair No. 1 and Pair No. 2)
POINT
POINT
POINT
Precautions for making MELSEC redundant setting
Pay attention to the following items when making the MELSEC redundant setting.
• Pairing of the last station No. and station No. 1 (Example: Station No. 64 and station No. 1) is
not allowed.
• Make sure that the QCPU in the station for which MELSEC redundant setting is made is a
redundant CPU.
If any of the QCPUs to which the MELSEC redundant setting is made is not a redundant CPU,
the GOT fails to automatically change the monitoring target to the control system when the
system is switched.
• When making the MELSEC redundant setting for MELSECNET/H, MELSECNET/10, or
Ethernet connections, check the station Nos. of network modules before the setting. If the
settings of the MELSEC redundant setting and the actual network module station Nos. are not
matched, the GOT fails to automatically change the monitoring target to the control system
when the system is switched.
• GOT supports the backup mode, which is the redundant mode of the RCPU redundant system,
and does not support the process mode and separate mode.
• GOT supports the backup mode, which is the operation mode of the QCPU redundant system,
and does not support the debug mode and separate mode.
GOT
1) Process CPU
2) Redundant function module
3) Tracking cable
4) CC-Link IE Filed Network Master/Local module
N/W No.: 1(virtual)
PC No.: 1(virtual)
IP address: 192.168.3.1
Port No.: 5006
N/W No.: 1(virtual)
PC No.: 2(virtual)
IP address: 192.168.3.2
Port No.: 5006
4)
2)
1)
1) 2) 4)
2) 4)
2) 4)
1)
1)
3)
3)
N/W No.: 1(virtual)
PC No.: 3(virtual)
IP address: 192.168.3.3
Port No.: 5006
N/W No.: 1(virtual)
PC No.: 4(virtual)
IP address: 192.168.3.4
Port No.: 5006
N/W No.: 1(virtual)
PC No.: 5(virtual)
IP address: 192.168.3.18
Port No.: 5001
Control system (system A)
Standby system (system B)
Control system
(system A)
Standby system (system B)
Ethernet
(Pair No.2)
(Pair No.1)
Summary of Contents for GOT2000 Series
Page 2: ......
Page 84: ......
Page 432: ...6 58 6 6 Precautions ...
Page 578: ...9 54 9 6 Precautions ...
Page 726: ...12 84 12 5 Precautions ...
Page 756: ......
Page 822: ...14 66 14 4 Device Range that Can Be Set ...
Page 918: ...15 96 15 7 Precautions ...
Page 930: ...16 12 16 6 Precautions ...
Page 964: ......
Page 1002: ...19 38 19 7 Precautions ...
Page 1022: ...20 20 20 5 Precautions ...
Page 1023: ...MULTI CHANNEL FUNCTION 21 MULTI CHANNEL FUNCTION 21 1 ...
Page 1024: ......
Page 1054: ...21 30 21 5 Multi channel Function Check Sheet ...
Page 1055: ...FA TRANSPARENT FUNCTION 22 FA TRANSPARENT FUNCTION 22 1 ...
Page 1056: ......
Page 1223: ......