6.5 PLC Side Setting
6 - 55
6
DIRECT CONNEC
T
ION T
O
CPU
6.5.2
GX Works2 settings
Set the communication speed in GX Works2.
Step 1.
Click [PLC parameter]
[Adapter Serial Setting].
Step 2.
Set [RS-422/485] in [Adapter Type].
Step 3.
Set [GOT Connection] in [Select Function].
Step 4.
Adjust [Communication Speed Setting] with the GOT communication setting.
➠
6.4.2 Communication detail settings
POINT
POINT
POINT
L6ADP-R4 adapter
For details on the L6ADP-R4 adapter, refer to the following manual.
➠
MELSEC-L CPU Module User's Manual (Hardware Design, Maintenance and
Inspection)