12.2 System Configuration
12 - 11
CC-Link
C
O
NN
ECTION (INTELLIGE
NT DEVICE ST
A
T
ION)
12
12.2.3
Connecting with CC-Link Ver.1/Ver.2 compatibles mixed
*1
For the system configuration of the CC-Link module, refer to the following manual.
➠
CC-Link System Master/Local Module User's Manual QJ61BT11N
*2
For the specifications and inquiries of the CC-Link dedicated cable, refer to the following.
➠
CC-Link Partner Association's home page: http://www.cc-link.org/
*3
The maximum overall extension cable length and the length between stations vary depending on the cable type to be used and
the transmission speed.
For details, refer to the following manual.
➠
CC-Link System Master/Local Module User's Manual QJ61BT11N
FX3U-16CCL-M USER'S MANUAL
*4
Specify Ver.2 as the mode setting in the Communication Settings to use it.
For details of the settings, refer to the following the manual.
➠
12.3.1 Setting communication interface (Controller Setting)
*5
Specify Ver.1 as the mode setting in the Communication Settings to use it.
For details of the settings, refer to the following the manual.
➠
12.3.1 Setting communication interface (Controller Setting)
*6
When using an FX3U-16CCL-M with the MELSEC iQ-F series, bus conversion module (FX5-CNV-BUS or FX5-CNV-BUSC) is
required.
*7
MELSEC-FX do not support FX5-CCL-MS.
*8
GT25-W, GT2505-V does not support the option device.
PLC
Connection cable
GOT
Number of
connectable
equipment
Model name
CC-Link module
*1
Communication
type
Cable model
Max.
distance
Option device
*8
Model
MELSEC iQ-R
Series
Motion controller
CPU (MELSEC iQ-
R Series)
C Controller
module (MELSEC
iQ-R Series)
CNC C80
CR800-
R(R16RTCPU)
RJ61BT11
CC-Link (Ver.2)
CC-Link dedicated
cable
*2
*3
GT15-J61BT13
*4
26 GOTs
CC-Link (Ver.1)
CC-Link dedicated
cable
*2
*3
GT15-J61BT13
*5
MELSEC-Q
(Q mode)
C Controller
module
(Q Series)
Motion controller
CPU (Q Series)
CNC C70
Robot controller
(CRnQ-700)
QJ61BT11N
CC-Link (Ver.2)
CC-Link dedicated
cable
*2
*3
GT15-J61BT13
*4
CC-Link (Ver.1)
CC-Link dedicated
cable
*2
*3
GT15-J61BT13
*5
MELSEC iQ-F
series
*6
MELSEC-FX
*7
FX3U-16CCL-M
FX5-CCL-MS
CC-Link (Ver.2)
CC-Link dedicated
cable
*2
*3
GT15-J61BT13
*4
8 GOTs
CC-Link (Ver.1)
CC-Link dedicated
cable
*2
*3
CC-Link
module
QCPU
GOT
Connection cable
CC-Link Ver2(ID)
Communication driver
Summary of Contents for GOT2000 Series
Page 2: ......
Page 84: ......
Page 432: ...6 58 6 6 Precautions ...
Page 578: ...9 54 9 6 Precautions ...
Page 726: ...12 84 12 5 Precautions ...
Page 756: ......
Page 822: ...14 66 14 4 Device Range that Can Be Set ...
Page 918: ...15 96 15 7 Precautions ...
Page 930: ...16 12 16 6 Precautions ...
Page 964: ......
Page 1002: ...19 38 19 7 Precautions ...
Page 1022: ...20 20 20 5 Precautions ...
Page 1023: ...MULTI CHANNEL FUNCTION 21 MULTI CHANNEL FUNCTION 21 1 ...
Page 1024: ......
Page 1054: ...21 30 21 5 Multi channel Function Check Sheet ...
Page 1055: ...FA TRANSPARENT FUNCTION 22 FA TRANSPARENT FUNCTION 22 1 ...
Page 1056: ......
Page 1223: ......