12 - 16
12.4 PLC Side Setting
12.4 PLC Side Setting
The GOT operates as the stations of which are shown below in the CC-Link system.
The switch settings and parameter settings of the PLC side (CC-Link module) are described in 12.4.5 to 12.4.11.
POINT
POINT
POINT
Number of stations occupied
The number of stations occupied is setting for determining number of link device points (RX/RY/
RWw/RWr) used by the GOT.
To use multiple numbers of link device points in the case of cyclic transmission between the GOT
and CC-Link module, set the number of stations occupied as the exclusive station 4.
The number of link device points at the exclusive station 1 and 4 is shown below.
• CC-Link Ver.2
• CC-Link Ver.1
Station data
Description
Station type
Intelligent device station, Ver.1 intelligent device station or Ver.2 intelligent device station
Number of stations occupied
Station 1 or Station 4
Model name
Refer to
CC-Link module
(MELSEC iQ-R Series)
Connecting with Ver.1 compatible
RJ61BT11
➠
Connecting with Ver.2 compatible
RJ61BT11
➠
Connecting with Ver.1/Ver.2 compatibles mixed
RJ61BT11
➠
CC-Link module
(Q Series)
Connecting with Ver.1 compatible
QJ61BT11, QJ61BT11N
➠
Connecting with Ver.2 compatible
QJ61BT11N
➠
Connecting with Ver.1/Ver.2 compatibles mixed
QJ61BT11N
➠
CC-Link module
(QnA Series)
AJ61QBT11, A1SJ61QBT11
➠
CC-Link module
(A Series)
AJ61BT11, A1SJ61BT11
CC-Link module
(MELSEC iQ-F Series, MELSEC-FX)
Connecting with Ver.1/Ver.2 compatibles mixed
FX3U-16CCL-M
➠
CC-Link module
(MELSEC iQ-F Series)
Ver.1/Ver.2 compatibles mixed
FX5-CCL-MS
➠
Link
device
Expanded cyclic setting
Single
Double
Quadruple
Octuple
Exclusive
station 1
Exclusive
station 4
Exclusive
station 1
Exclusive
station 4
Exclusive
station 1
Exclusive
station 4
Exclusive
station 1
Exclusive
station 4
Remote
input (RX)
32 points
128
points
32 points
224
points
64 points
448
points
128
points
896
points
Remote
output (RY)
32 points
128
points
32 points
224
points
64 points
448
points
128
points
896
points
Remote
register (RWw)
4 points
16 points
8 points
32 points
16 points
64 points
32 points
128
points
Remote
register (RWr)
4 points
16 points
8 points
32 points
16 points
64 points
32 points
128
points
Link device
Number of stations occupied
Exclusive station
Exclusive station 4
Remote input (RX)
32 points
128 points
Remote output (RY)
32 points
128 points
Remote register (RWw)
4 points
16 points
Remote register (RWr)
4 points
16 points
Summary of Contents for GOT2000 Series
Page 2: ......
Page 84: ......
Page 432: ...6 58 6 6 Precautions ...
Page 578: ...9 54 9 6 Precautions ...
Page 726: ...12 84 12 5 Precautions ...
Page 756: ......
Page 822: ...14 66 14 4 Device Range that Can Be Set ...
Page 918: ...15 96 15 7 Precautions ...
Page 930: ...16 12 16 6 Precautions ...
Page 964: ......
Page 1002: ...19 38 19 7 Precautions ...
Page 1022: ...20 20 20 5 Precautions ...
Page 1023: ...MULTI CHANNEL FUNCTION 21 MULTI CHANNEL FUNCTION 21 1 ...
Page 1024: ......
Page 1054: ...21 30 21 5 Multi channel Function Check Sheet ...
Page 1055: ...FA TRANSPARENT FUNCTION 22 FA TRANSPARENT FUNCTION 22 1 ...
Page 1056: ......
Page 1223: ......