12 - 74
12.4 PLC Side Setting
(c)
Buffer memory settings used in the present example
*1
Details for the station data are shown below.
For 1) and 2) and 3), set the same station No. and number of station occupied and expanded cyclic as those of the GOT.
Buffer memory address
Item
Set value
Decimal (Hex)
0(0H)
Mode
2 (Remote net (Ver.2 mode))
1(1H)
Number of connected modules
2 (2module)
2(2H)
Retry Count
7 (7times)
3(3H)
Automatic Reconnection Station Count
2 (2module)
6(6H)
PLC Down Select
0 (stop)
12(CH)
Data Link Disorder Station Setting
1 (Clear)
6(DH)
Case of CPU STOP Setting
0 (Refresh)
32(20H)
Station information (1st unit)
*1
2301H
33(21H)
Station information (2nd unit)
*1
C104H
1) Station No. (Set the same station No. as that of the GOT.)
01H to 10H: Station No.1 to Station No.16
2) Number of stations occupied (Set the same setting of the number of station occupied as that of the GOT.)
1H: Exclusive station 1
2H: Exclusive station 2
3H: Exclusive station 3
4H: Exclusive station 4
3) Station type
2H: Ver.1 compatible intelligent device station
6H: Ver.2 compatible single intelligent device station
9H: Ver.2 compatible double intelligent device station
CH: Ver.2 compatible quadruple intelligent device station
FH: Ver.2 compatible octuple intelligent device station
3)
2)
1)
b15
b12
to
b11
b8
to
b7
to
b0
Summary of Contents for GOT2000 Series
Page 2: ......
Page 84: ......
Page 432: ...6 58 6 6 Precautions ...
Page 578: ...9 54 9 6 Precautions ...
Page 726: ...12 84 12 5 Precautions ...
Page 756: ......
Page 822: ...14 66 14 4 Device Range that Can Be Set ...
Page 918: ...15 96 15 7 Precautions ...
Page 930: ...16 12 16 6 Precautions ...
Page 964: ......
Page 1002: ...19 38 19 7 Precautions ...
Page 1022: ...20 20 20 5 Precautions ...
Page 1023: ...MULTI CHANNEL FUNCTION 21 MULTI CHANNEL FUNCTION 21 1 ...
Page 1024: ......
Page 1054: ...21 30 21 5 Multi channel Function Check Sheet ...
Page 1055: ...FA TRANSPARENT FUNCTION 22 FA TRANSPARENT FUNCTION 22 1 ...
Page 1056: ......
Page 1223: ......