14 - 58
14.4 Device Range that Can Be Set
■2.
Inverter (FREQROL 500/700/800 series), sensorless servo (FREQROL-E700EX)
*1
When creating the screen, designate only either of programmed operation (PG) device or parameter (Pr) device.
Do no designate both PG (PG0 to PG89) and Pr (Pr900 to Pr905) devices.
*2
Only 16-bit (1-word) designation is possible.
*3
Only reading is possible.
*4
When the GOT is connected to the PU connector and the operation mode is set to the PU operation mode, the multi-speed
operation (W3 to W7, SP121, SP122) cannot be used.
For using the multi-speed operation, follow either of the operations as below.
• Connect the GOT to the RS-485 terminal and set the operation mode to the NET operation mode (Computer link operation
mode), and then operate the inverter.
• Change the motor speed with the set frequency (SP109, SP110), and then operate the inverter with the forward or reverse
rotation (WS1, WS2, SP121, SP122).
*5
Only writing is possible for WS devices.
More than one WS cannot turn on at once.
(Except the turned on WS device, the other WS devices turn off.)
Bits of SP122 (word device) and SP121 (word device) are assigned to WS0 to WS7 and WS8 to WS15 respectively.
When more than one WS turns on at once, convert the values for the bit devices that are assigned to the word device into values
for the word device. Write the converted values into SP122 or SP121.
• Setting High speed operation command (WS5), Middle speed operation command (WS4), and Low speed operation command
(WS3)
When setting High speed operation command (WS5), Middle speed operation command (WS4), and Low speed operation
command (WS3), write numerical values to device SP122 as necessary.
As the following figure shows, each operation mode is assigned to device SP122.
The following shows an example for Forward rotation command (WS1) and Low speed operation command (WS3).
Write 1 to the bits of device SP122 that correspond to the Forward rotation command (WS1) and Low speed operation command
(WS3).
In this example, device SP122 must store 000AH.
Convert 000AH to a decimal value (10), and then write 10 to device SP122.
• Setting the JOG operation command (WS8), Selection of automatic restart after instantaneous power failure command (WS9),
Start self-holding selection command (WS10), and Reset command (WS11)
When setting the above commands, write values to device SP121 as necessary.
As shown in the figure below, each operation mode is assigned to a bit of device SP121.
The following shows an example of setting the Reset command (WS11).
Device name
Setting range
Device
No. representation
Bit device
Inverter
status monitor
(RS)
*3
0-0 RS0 to 0-31 RS15
0-100 RS0 to 0-115 RS15
Decimal
Run command (WS)
*4*5
0-0 WS0 to 0-31 WS15
0-100 WS0 to 0-115 WS15
Word device
Alarm definition (A)
*2*3
0-0 A0 to 0-31 A7
0-100 A0 to 0-115 A7
Decimal
Parameter (Pr)
*1*2
0-0 Pr0 to 0-31 Pr1500
0-100 Pr0 to 0-115 Pr1500
Programmed operation
(PG)
*1*2
0-0 PG0 to 0-31 PG89
0-100 PG0 to 0-115 PG89
Special parameter
(SP)
*2*4*5
0-0 SP108 to 0-31 SP127
0-100 SP108 to 0-115 SP127
Device SP122
b15
b7
b0
0 0 0 0 0 0 0 0 0 0 0 0 1 0 1 0
WS7: Output stop(MRS)
WS6: Second function selection(RT)
WS5: High speed operation command(RH)
WS4: Middle speed operation command(RM)
WS3: Low speed operation command(RL)
WS2: Reverse rotation command(STR)
WS1: Forward rotation command(STF)
WS0: Current input selection(AU)
Summary of Contents for GOT2000 Series
Page 2: ......
Page 84: ......
Page 432: ...6 58 6 6 Precautions ...
Page 578: ...9 54 9 6 Precautions ...
Page 726: ...12 84 12 5 Precautions ...
Page 756: ......
Page 822: ...14 66 14 4 Device Range that Can Be Set ...
Page 918: ...15 96 15 7 Precautions ...
Page 930: ...16 12 16 6 Precautions ...
Page 964: ......
Page 1002: ...19 38 19 7 Precautions ...
Page 1022: ...20 20 20 5 Precautions ...
Page 1023: ...MULTI CHANNEL FUNCTION 21 MULTI CHANNEL FUNCTION 21 1 ...
Page 1024: ......
Page 1054: ...21 30 21 5 Multi channel Function Check Sheet ...
Page 1055: ...FA TRANSPARENT FUNCTION 22 FA TRANSPARENT FUNCTION 22 1 ...
Page 1056: ......
Page 1223: ......