15 - 68
15.6 Device Range that Can Be Set
■9.
MELSERVO-J4-*A, -JE-*A
*1
Use 1 to 80 of PA, PB, PC, PD, PE, PL and PF when the GOT writes data to RAM of the servo amplifier.
Use 1001 to 1080 of PA, PB, PC, PD, PE, PF and PL when the GOT write data to E
2
PROM of the servo amplifier.
Use PA, PB, PC, PD, PE, PF, PL 1001 to 1080 when reading parameters to the servo amplifier RAM.
*2
The GOT cannot read or write data from/to consecutive devices.
*3
Only reading is possible.
*4
Only reading is possible for DI0 to DI1.
*5
Only writing is possible.
*6
These devices cannot be used for MELSERVO-JE
Device name
*2
Setting range
Device No.
represen tation
Bit device
Servo amplifier request (SP)
SP0 to SP6
Decimal
Operation mode selection (OM)
OM0 to OM2
OM4
Instruction demand (for test operation) (TMB)
TMB1 to TMB6
One-touch tuning command (OTI)
*5
OTI0 to OTI5
Word device
Basic setting parameter (PA)
*1
PA1 to PA32
PA1001 to PA1032
Gain filter parameter (PB)
*1
PB1 to PB64
PB1001 to PB1064
Extension setting parameter (PC)
*1
PC1 to PC80
PC1001 to PC1080
I/O setting parameter (PD)
*1
PD1 to PD48
PD1001 to PD1048
Extension setting 2 parameter (PE)
*1
PE1 to PE64
PE1001 to PE1064
Extension setting 3 parameter (PF)
*1
PF1 to PF48
PF1001 to PF1048
Linear servo motor/DD motor setting parameter (PL)
*2*6
PL1 to PL48
PL1001 to PL1048
Status display (ST)
*3
ST0 to ST41
Alarm (AL)
*3
AL0 to AL1
AL11 to AL25
AL200 to AL205
AL210 to AL215
AL230 to AL235
Alarm (ALM)
*3
ALM0 to ALM1
ALM11 to ALM52
ALM200 to ALM215
ALM220 to ALM235
ALM240 to ALM255
Machine diagnosis data (MD)
*3
MD0 to MD11
One-touch tuning data (OTS)
*3
OTS0 to OTS3
External input (DI)
*4
DI0 to DI2
External output (DO)
*3
DO0 to DO1
Lifetime diagnosis (ALD)
*3
ALD0 to ALD1
Double word device
Input signal for test operation (for test operation) (TM0)
TMI0
Forced output of signal pin (for test operation) (TMO)
TMO0
Set data (for test operation) (TMD)
TMD0 to TMD1
TMD3
Summary of Contents for GOT2000 Series
Page 2: ......
Page 84: ......
Page 432: ...6 58 6 6 Precautions ...
Page 578: ...9 54 9 6 Precautions ...
Page 726: ...12 84 12 5 Precautions ...
Page 756: ......
Page 822: ...14 66 14 4 Device Range that Can Be Set ...
Page 918: ...15 96 15 7 Precautions ...
Page 930: ...16 12 16 6 Precautions ...
Page 964: ......
Page 1002: ...19 38 19 7 Precautions ...
Page 1022: ...20 20 20 5 Precautions ...
Page 1023: ...MULTI CHANNEL FUNCTION 21 MULTI CHANNEL FUNCTION 21 1 ...
Page 1024: ......
Page 1054: ...21 30 21 5 Multi channel Function Check Sheet ...
Page 1055: ...FA TRANSPARENT FUNCTION 22 FA TRANSPARENT FUNCTION 22 1 ...
Page 1056: ......
Page 1223: ......