17.4 GOT Side Settings
17 - 13
17
CNC CONNECTION
■4.
Ethernet(MITSUBISHI ELECTRIC), Gateway
*1
Each of [GOT Station] set in the communication detail setting and [Station] set in the Ethernet setting must be set to different
station numbers.
➠
POINT
POINT
POINT
(1) Communication interface setting by Utility
The communication interface setting can be changed on the Utility's [Communication
Settings] after writing [Controller Setting] of project data.
For details on the Utility, refer to the following manual.
➠
GOT2000 Series User's Manual (Utility)
(2) Precedence in communication settings
When settings are made by GT Designer3 or the Utility, the latest setting is effective.
Item
Description
Range
GOT Net No.
Set the network No. of the GOT. (Default: 1)
1 to 239
GOT Station
*1
Set the station No. of the GOT. (Default: 18)
1 to 64
GOT Communication Port No.
Set the GOT port No. for the connection with the Ethernet module.
(Default: 5001)
1024 to 5010 to 5014 to 65534
(Except for 5011, 5012, 5013 and
49153 to 49170)
Retry
Set the number of retries to be performed when a communication
timeout occurs.
When receiving no response after retries, the communication times out.
(Default: 3times)
0 to 5times
Startup Time
Specify the time period from the GOT startup until GOT starts the
communication with the PLC CPU. (Default: 3sec)
3 to 255sec
Timeout Time
Set the time period for a communication to time out. (Default: 3sec)
3 to 90sec
Delay Time
Set the delay time for reducing the load of the network/destination PLC.
(Default: 0ms)
0 to 10000 ( 10ms)
Servo axis switching GD device
head No.
Set the servo axis switching GD device head No.
(Default: 10)
<For GT27, GT25, GT23>
0 to 65520
<For GT21, GS>
0 to 2032
Summary of Contents for GOT2000 Series
Page 2: ......
Page 84: ......
Page 432: ...6 58 6 6 Precautions ...
Page 578: ...9 54 9 6 Precautions ...
Page 726: ...12 84 12 5 Precautions ...
Page 756: ......
Page 822: ...14 66 14 4 Device Range that Can Be Set ...
Page 918: ...15 96 15 7 Precautions ...
Page 930: ...16 12 16 6 Precautions ...
Page 964: ......
Page 1002: ...19 38 19 7 Precautions ...
Page 1022: ...20 20 20 5 Precautions ...
Page 1023: ...MULTI CHANNEL FUNCTION 21 MULTI CHANNEL FUNCTION 21 1 ...
Page 1024: ......
Page 1054: ...21 30 21 5 Multi channel Function Check Sheet ...
Page 1055: ...FA TRANSPARENT FUNCTION 22 FA TRANSPARENT FUNCTION 22 1 ...
Page 1056: ......
Page 1223: ......