22 - 92
22.7 Personal Computer Side Setting
22.7.4
Accessing by GX Works2
The following shows the procedure to set the FA transparent function of GX Works2.
■1.
When connecting the GOT and the personal computer by USB
(1) Connecting the GOT and PLC in bus connection or direct CPU connection (when connecting to
QCPU (Q mode))
Step 1.
Click the Connection Destination view
[Connection Destination]
[(Connection target data name)] in
the Navigation window of GX Works2.
Step 2.
The [Transfer Setup Connection1] is displayed.
Step 3.
Set the [Transfer Setup Connection1]:
PC side I/F: Serial USB
PLC side I/F: GOT
Other Station Setting: No Specification:
Step 4.
Double-click [Serial USB] of the PC side I/F to display [PC side I/F Serial Setting].