22.7 Personal Computer Side Setting
22 - 115
22
FA TRANSP
ARE
NT FU
NCTION
22.7.5
Accessing by GX LogViewer
The following shows the procedure to set the FA transparent function of GX LogViewer.
Step 1.
Click [Show Assistant Dialog] for [View] on GX LogViewer.
Step 2.
The [Assistant] dialog box is displayed.
Step 3.
Click [LCPU]
[Show Logged Device Status] in the [Assistant] dialog box.
Step 4.
The [Transfer Setup Connection 1] dialog box is displayed.
Step 5.
Set the [Transfer Setup Connection 1]:
PC side I/F: Serial USB
PLC side I/F: GOT
Other Station Setting: (Select from the system configuration)
Step 6.
For [PC side I/F Serial Setting] and [PLC side I/F Detailed Setting of GOT] of [Transfer Setup], refer to the
following.
➠