4 - 68
4.2 MELSEC Q Series
4.2.5
MELSECNET/H and MELSECNET/10 Connections (Network Systems)
This section explains the MELSECNET/H and MELSECNET/10 connections (network systems) that connect the GOT to the
MELSECNET/H and MELSECNET/10 network system.
The following provides an example of connecting the GOT set as a normal station to the MELSECNET/ H network system.
■1.
Connection method
Connect the MELSECNET/H network system to the GOT.
For details, refer to the following.
➠
9. MELSECNET/H CONNECTION (PLC TO PLC NETWORK), MELSECNET/10 CONNECTION
(PLC TO PLC NETWORK)
■2.
GT Designer3 setting
Set GT Designer3 as follows.
■3.
Monitoring target change when system switching occurs in a redundant system
When system switching occurs, the network module station No. 2 changes from the normal station to the sub control
station and takes over the control of the MELSECNET/H network system.
Since the GOT monitors the control system, the monitoring target is automatically changed to the network module
station No. 2.
POINT
POINT
POINT
To monitor the control system without MELSEC redundant setting
When system switching occurs, the network module station No. 2 changes from the normal
station to the sub control station and takes over the control of the MELSECNET/H network
system.
Since the GOT monitors the station of the specified station number, the monitoring target cannot
be changed to the station No. 2 in response to the system switching.
As a countermeasure, create a screen to monitor the PLC CPU of the control system by
switching the station numbers between System A and System B using the script function.
➠
4.2.9Switch the Monitor Target to the Control System Using the Script Function
Setting item
Settings
Model
Controller Type
MELSEC-QnA, MELDAS C6*
Device setting (Network setting)
Other
NW No.: Network No. of MELSECNET/H PLC to PLC network
Station No.: Station number of the control system
MELSEC Redundant Setting
➠
Monitor target
MELSECNET/H remote I/O network
Po
w
e
r
s
u
ppl
y
mo
d
u
le
Em
p
ty
Em
p
ty
GOT
Network No. 1, Station No. 1
(Control station)
Control
system
(System A)
Em
p
ty
Q25PRHCPU
QJ71LP21-25
QJ71BR1
1
QJ71E71-100
QJ61BT1
1N
Em
pty
Standby
system
(System B)
Q25PRHCPU
QJ71LP21-25
QJ71BR1
1
QJ71E71-100
QJ61BT1
1N
QJ72LP25-25
QJ71C24N
Network No. 1, Station No. 3 (Normal station)
Network No. 1, Station No. 2
(Normal station)
MELSECNET/H PLC to PLC network
(MELSECNET/H mode or
MELSECNET/10 mode)
P
o
we
r
s
u
p
p
ly
mo
d
u
le
Po
w
e
r
s
u
ppl
y
mo
d
u
le
Summary of Contents for GOT2000 Series
Page 2: ......
Page 84: ......
Page 432: ...6 58 6 6 Precautions ...
Page 578: ...9 54 9 6 Precautions ...
Page 726: ...12 84 12 5 Precautions ...
Page 756: ......
Page 822: ...14 66 14 4 Device Range that Can Be Set ...
Page 918: ...15 96 15 7 Precautions ...
Page 930: ...16 12 16 6 Precautions ...
Page 964: ......
Page 1002: ...19 38 19 7 Precautions ...
Page 1022: ...20 20 20 5 Precautions ...
Page 1023: ...MULTI CHANNEL FUNCTION 21 MULTI CHANNEL FUNCTION 21 1 ...
Page 1024: ......
Page 1054: ...21 30 21 5 Multi channel Function Check Sheet ...
Page 1055: ...FA TRANSPARENT FUNCTION 22 FA TRANSPARENT FUNCTION 22 1 ...
Page 1056: ......
Page 1223: ......