17 - 4
17.2 System Configuration
17.2.2
MELSECNET/10 connection (PLC to PLC network)
POINT
POINT
POINT
(1) Connectable network
MELSECNET/10 connection includes the case that MELSECNET/H is used in NET/10
mode.The GOT cannot be connected to the remote I/O network.
Connect the GOT to the following network systems as an ordinary station.
• MELSECNET/10 network system (PLC to PLC network) optical loop system
• MELSECNET/10 network system (PLC to PLC network) coaxial bus system
(2) MELSECNET/H network module
When connecting the MELSECNET/H network module to the MELSECNET/10 network
system, specify the MELSECNET/10 Mode as a network type.
*1
The overall extension cable length and the length between stations vary depending on the cable type to be used and the total
number of stations.
For details, refer to the following manuals.
➠
C6/C64/C64T CONNECTION AND MAINTENANCE MANUAL BNP-B2255
➠
C6/C64/C64T NETWORK INSTRUCTION MANUAL BNP-B2373
*2
Specify the MELSECNET/10 Mode as the Communication Settings.For the setting, refer to the following.
➠
17.4.1 Setting communication interface (Controller Setting)
*3
For the coaxial cable and optical fiber cable, refer to the following manuals.
➠
C6/C64/C64T CONNECTION AND MAINTENANCE MANUAL BNP-B2255
➠
C6/C64/C64T NETWORK INSTRUCTION MANUAL BNP-B2373
*4
GT25-W, GT2505-V does not support the option device.
CNC
Connection cable
GOT
Number of
connectable
equipment
Model name
Expansion unit
Communication type
Cable model
Max.
distance
Option device
*4
Model
MELDAS C6/C64
FCU6-EX878
MELSECNET/10
(Coaxial bus system)
Coaxial cable
*3
*1
GT15-J71BR13
*2
31 GOTs
FCU6-EX879
MELSECNET/10
(Optical loop system)
Optical fiber cable
*3
*1
GT15-J71LP23-25
*2
63 GOTs
Expansion
unit
GOT
Connection cable
MELDAS
C6/C64
MELSECNET/H
Communication driver
(When MELSECNET/H
communication unit is used)
Summary of Contents for GOT2000 Series
Page 2: ......
Page 84: ......
Page 432: ...6 58 6 6 Precautions ...
Page 578: ...9 54 9 6 Precautions ...
Page 726: ...12 84 12 5 Precautions ...
Page 756: ......
Page 822: ...14 66 14 4 Device Range that Can Be Set ...
Page 918: ...15 96 15 7 Precautions ...
Page 930: ...16 12 16 6 Precautions ...
Page 964: ......
Page 1002: ...19 38 19 7 Precautions ...
Page 1022: ...20 20 20 5 Precautions ...
Page 1023: ...MULTI CHANNEL FUNCTION 21 MULTI CHANNEL FUNCTION 21 1 ...
Page 1024: ......
Page 1054: ...21 30 21 5 Multi channel Function Check Sheet ...
Page 1055: ...FA TRANSPARENT FUNCTION 22 FA TRANSPARENT FUNCTION 22 1 ...
Page 1056: ......
Page 1223: ......