JY997D22801L

Safety Precaution

 

(Read these precautions before using.)

Before using this product, please read this manual and the relevant manuals
introduced in this manual carefully and pay full attention to safety to handle the
product correctly.
The precautions given in this manual are concerned with this product.
In this manual, the safety precautions are ranked as "WARNING" and
"CAUTION".

Depending on circumstances, procedures indicated by "CAUTION" may also be
linked to serious results. 
In any case, it is important to follow the directions for usage.       

Indicates that incorrect handling may cause hazardous
conditions, resulting in death or severe injury.

Indicates that incorrect handling may cause hazardous
conditions, resulting in medium or slight personal injury
or physical damage.

DESIGN PRECAUTIONS

Some failures of the GOT or cable may keep the outputs on or off.

An external monitoring circuit should be provided to check for output signals

which may lead to a serious accident.

Not doing so can cause an accident due to false output or malfunction.

If a communication fault (including cable disconnection) occurs during

monitoring on the GOT, communication between the GOT and PLC CPU is

suspended and the GOT becomes inoperative.

A system where the GOT is used should be configured to perform any

significant operation to the system by using the switches of a device other

than the GOT on the assumption that a GOT communication fault will occur.

Not doing so can cause an accident due to false output or malfunction.

Do not use the GOT as the warning device that may cause a serious

accident.

An independent and redundant hardware or mechanical interlock is required

to configure the device that displays and outputs serious warning.

Failure to observe this instruction may result in an accident due to incorrect

output or malfunction.

Incorrect operation of the touch switch(s) may lead to a serious accident if the

GOT backlight is gone out.

When the GOT backlight goes out, the POWER LED flickers (green/orange)

and the display section turns black and causes the monitor screen to appear

blank, while the input of the touch switch(s) remains active.

This may confuse an operator in thinking that the GOT is in "screensaver"

mode, who then tries to release the GOT from this mode by touching the

display section, which may cause a touch switch to operate.

Note that the following occurs on the GOT when the backlight goes out.

- The POWER LED flickers (green/orange) and the monitor screen appears 

blank

DESIGN PRECAUTIONS

Do not bundle the control and communication cables with main-circuit, power or

other wiring. Run the above cables separately from such wiring and keep them a

minimum of 100mm (3.94in.) apart.Not doing so noise can cause a malfunction.

Do not press the GOT display section with a pointed material as a pen or driver.

Doing so can result in a damage or failure of the display section.

Before connecting to GOT, turn ON the controller to enable the communication.

When the communication of controller is not available, a communication error

may occur in GOT.

MOUNTING PRECAUTIONS

Be sure to shut off all phases of the external power supply used by the system

before mounting or removing the GOT to/from the panel.

Not doing so can cause the unit to fail or malfunction.

Always turn off the power ON/OFF switch on the connector conversion box before

connecting or disconnecting the GOT to it.

Connecting or disconnecting the GOT with the power being turned on may result

in damage to the unit or malfunctions.

Be sure to shut off all phases of the external power supply used by the system

before mounting or removing the relay cable onto/from the GOT.

Be sure to shut off all phases of the external power supply used by the system

before mounting or removing the option function board on to/from the GOT. Not

doing so can cause the unit to fail or malfunction.

When installing the option function board or battery, or operating the reset switch,

wear an earth band etc. to avoid the static electricity.

The static electricity can cause the unit to fail or malfunction.

MOUNTING PRECAUTIONS

Use the GOT in the environment that satisfies the general specifications

described in this manual. Not doing so can cause an electric shock, fire,

malfunction or product damage or deterioration.

Never drop cutting chips and electric wire chips into the ventilation window of the

Handy GOT when you drill screw holes or perform wiring.

Otherwise, fire, failure or malfunction may be caused.

Connect connection cables securely to the specified connectors while the power

is turned OFF.

Imperfect connection may cause malfunction or failure.

When connecting cables, pay attention to the contents described in this section.

Especially, attach the rear cover so that PCBs inside the Handy GOT are not

interfered with connection cables.

Securely connect the option function board to the connector provided for the

board.

When inserting/removing a CF card into/from the GOT, turn the CF card access

switch off in advance. Failure to do so may corrupt data within the CF card.

When inserting a CF card into the GOT, push it into the insertion slot until the CF

card eject button will pop out. Failure to do so may cause a malfunction due to

poor contact.

When removing a CF card from the GOT, make sure to support the CF card by

hand, as it may pop out. Failure to do so may cause the CF card to drop from the

GOT and break.

WIRING PRECAUTIONS

Make sure to attach the back cover to the Handy GOT before turning on the

power and starting operation after the installation or wiring work.

Otherwise, electrical shock may be caused.

Be sure to shut off all phases of the external power supply used by the system

before wiring. Failure to do so may result in an electric shock, product damage or

malfunctions.

Please make sure to ground FG terminal of the GOT power supply section by

applying 100 or less which is used exclusively for the GOT. Not doing so may

cause an electric shock or malfunction.

Correctly wire the GOT power supply section after confirming the rated voltage

and terminal arrangement of the product. Not doing so can cause a fire or failure.

Exercise care to avoid foreign matter such as chips and wire offcuts entering the

GOT. Not doing so can cause a fire, failure or malfunction.

Associated Manuals

The following manuals are relevant to this product. When these loose manuals are required, please consult with our local distributor.

*1 The manual in PDF-format is included in the GT Works2/GT Designer2/GT Works3/GT Designer3 products.

For details of a PLC to be connected, refer to the PLC user's manual respectively.

Bundled Items

WIRING PRECAUTIONS

The cables connected to the unit must be run in ducts or clamped.

Not doing so can cause the unit or cable to be damaged due to the dangling,

motion or accidental pulling of the cables or can cause a malfunction due to a

cable connection fault.

When unplugging the cable connected to the unit, do not hold and pull the cable

portion.

Doing so can cause the unit or cable to be damaged or can cause a malfunction

due to a cable connection fault.

Plug the communication cable into the connector of the connected unit and

tighten the mounting and terminal screws in the specified torque range.

Undertightening can cause a short circuit or malfunction. Overtightening can

cause a short circuit or malfunction due to the damage of the screws or unit.

TEST OPERATION 
PRECAUTIONS

Before performing the test operations of the user creation monitor screen (such

as turning ON or OFF bit device, changing the word device current value,

changing the settings or current values of the timer or counter, and changing the

buffer memory current value), read through the manual carefully and make

yourself familiar with the operation method.

During test operation, never change the data of the devices which are used to

perform significant operation for the system. False output or malfunction can

cause an accident.

STARTUP/MAINTENANCE 
PRECAUTIONS

When power is on, do not touch the terminals.

Doing so can cause an electric shock or malfunction.

Connect the battery correctly. Do not discharge, disassemble, heat, short,

solder or throw the battery into the fire. Incorrect handling may cause the battery

to generate heat, burst or take fire, resulting in injuries or fires.

Before starting cleaning or terminal screw retightening, always switch off the

power externally in all phases. Not switching the power off in all phases can

cause a unit failure or malfunction. Undertightening can cause a short circuit or

malfunction. Overtightening can cause a short circuit or malfunction due to the

damage of the screws or unit.

STARTUP/MAINTENANCE 
PRECAUTIONS

Do not disassemble or modify the unit.

Doing so can cause a failure, malfunction, injury or fire.

Do not touch the conductive and electronic parts of the unit directly.

Doing so can cause a unit malfunction or failure.

The cables connected to the unit must be run in ducts or clamped.

Not doing so can cause the unit or cable to be damaged due to the dangling,

motion or accidental pulling of the cables or can cause a malfunction due to a

cable connection fault.

When unplugging the cable connected to the unit, do not hold and pull the cable

portion. Doing so can cause the unit or cable to be damaged or can cause a

malfunction due to a cable connection fault.

Replace battery with GT11-50BAT by Mitsubishi electric Co. only.

Use of another battery may present a risk of fire or explosion.

Dispose of used battery promptly.

Keep away from children. Do not disassemble and do not dispose of in fire.

DISPOSAL PRECAUTIONS

When disposing of the product, handle it as industrial waste.

When disposing of batteries, separate them from other wastes according to the

local regulations.

(For details of the battery directive in EU member states, refer GOT User's

Manual.)

TRANSPORTATION 
PRECAUTIONS

When transporting lithium batteries, make sure to treat them based on the

transport regulations. (Refer to User's Manual for details of the regurated

models.)

Before transporting the GOT, turn the GOT power on and check that the battery

voltage status is normal on the Time setting & display screen (utilities screen). In

addition, confirm that the adequate battery life remains on the rating plate.

Transporting the GOT with the low battery voltage or the battery the reached

battery life may unstabilize the backup data unstable during transportation.

Make sure to transport the GOT main unit and/or relevant unit(s) in the manner

they will not be exposed to the impact exceeding the impact resistance

described in the general specifications of this manual, as they are precision

devices. Failure to do so may cause the unit to fail.

Check if the unit operates correctly after transportation.

Manual name

Contents

Manual Number

(Model Code)

GT Designer2 Version2 Basic Operation/Data

Transfer Manual (For GOT1000 Series)
(sold separately) 

*1

Describes methods of the GT Designer2 installation operation, basic operation for drawing

and transmitting data to GOT1000 series

SH-080529ENG

(1D7M24)

GT Designer2 Version2 Screen Design Manual

(For GOT1000 Series) 1/3, 2/3, 3/3
(sold separately) 

*1

Describes specifications and settings of the object functions used in GT Designer2

SH-080530ENG

(1D7M25)

GT Designer3 Version1 Screen Design Manual

(For GOT1000 Series) (Fundamentals) 1/2, 2/2

(sold separately) *1

Describes methods of the GT Designer3 installation operation, basic operation for drawing

and transmitting data to GOT1000 series

SH-080866ENG

(1D7MB9)

GT Designer3 Version1 Screen Design Manual

(For GOT1000 Series) (Functions) 1/2, 2/2

(sold separately) *1

Describes specifications and settings of the object functions used in GT Designer3

 SH-080867ENG

(1D7MC1)

GT11 Handy GOT User’s Manual

(Hardware/Utility, Connection) 1/2, 2/2

(sold separately)

Describes the Handy GOT hardware-relevant content such as part names, external

dimensions, mounting, power supply wiring, specifications, and introduction to option

devices

JY997D20101 

JY997D20102 

(09R817)

Product 

Name

Model 

Name

Specifications

GOT

GT1155HS

-QSBD

[320 

 240 dots], STN color LCD (256 colors), built-in

battery and backlight

GT1150HS

-QLBD

[320 

 240 dots], STN monochrome LCD (black/white, 16

scales), built-in battery and backlight

Bundled item

Quantity

Operation switch name character sheets
1) OHP sheet
2) Reference dimension sheet (switch name change sheet

mount)

1) One sheet
2) One sheet

Selector switch keys

2

GT11 Handy GOT General Description (This manual)

1

1. Features

1) Improved monitoring performance and connectivity to FA devices

- Two types of display modes are provided: 256-color display and monochrome display. In the monochrome display, 16 scales are used to improve the display.
- High speed monitoring through high speed communication at maximum of 115.2kbps.
- Multiple languages are displayed using the Unicode2.1-compatible fonts and beautiful characters are drawn using the TrueType and high quality fonts.
- High speed display and high speed touch switch response.

2) More efficient GOT operations including screen design, startup, adjustment, management and maintenance works

- The display screen of the display unit is created using a drawing software for PC (GT Designer2 Ver2.18U or later/GT Designer3 Ver1.01B or later).
- The 3MB user memory is included as standard.
- CF card interface is included as standard.
- The USB connector interface is included as standard.

3) Enhanced support of FA device setup tools

- Transferring or monitoring the sequence programs using the personal computer connected to GOT is available, during direct connection to A, QnA, L, Q, or FX series 

PLC CPU (FA Transparent function).

2. Part Name

2.1 Front Panel

For the PC connection, refer to the following.



GT11 Handy GOT User’s Manual

No

Name

Specifications

(1)

Keylock switch (2-position SW)

Switch for external direct wiring (independent contact)

(2)

Emergency stop switch

Switch for external direct wiring (independent contact)

(3)

Logo (2 places)

Removable

(4)

Display section

Displays the utility screen and the user creation screen.

(5)

Touch panel

For touch switch operation on the utility screen and the user creation screen.

(6)

Operation switch name sheet installation

place

Place (concave shape) where the operation switch name sheet (created by user) is installed.

(7)

Operation switch name sheet cover

Transparent cover to fix the operation switch name sheet (created by user) (removed when a sheet is inserted).

(8)

Display LED for grip switch

Display LED for grip switch (green) (lighting control from display section)

(9)

External interface connector

For external connection cable connection (for PLC, switch and power supply external wiring) 

(connector: round 32 pins, male)

(10)

Operation switch (6 switches)

Switch for external direct wiring (independent contact)

(11)

Display LED for operation switch (6 LEDs)

Display LED for operation switch (green) (lighting control from display section)

(12)

POWER LED

Lit in green

: Power is correctly supplied.

Lit in orange

: Screen saving and backlight not lit.

Blinks in orange/green : Blown back light bulb.

Not lit

: Power is not supplied.

GRIP SW

F1

F2

F3

F4

F5

F6

(1)

(3)

(12)

(11) (10)

(9)

(8)

(2)

(3)

(4)(5)

Operation switch name sheet (prepared by the user)
installation example

(6)(7)

2.2 Back Panel

For the connection to the controller, microcomputer board or PC, refer to the
following.



GT11 Handy GOT User’s Manual

3. Specifications

3.1 General Specifications

*1 Do not use or store the GOT under pressure higher than the atmospheric pressure of altitude 0m (0ft.). Failure to observe this instruction may cause a malfunction.

When the air inside the control panel is purged by pressurization, the surface sheet may be lifted by high pressure. As a result, the touch panel may be difficult to press,

and the sheet may be peeled off.

*2 This indicates the section of the power supply to which the equipment is assumed to be connected between the public electrical power distribution network and the

machinery within the premises. Category 



 applies to equipment for which electrical power is supplied from fixed facilities. The surge voltage withstand level for up to the

raged voltage of 300 V is 2500 V.

*3 This index indicates the degree to which conductive material is generated in the environment where the equipment is used.

In pollution degree 2, only non-conductive pollution occurs but temporary conductivity may be produced due to condensation.

(3)

(3)

(7)

(1)

(1)

(2)

(5)

(4)

Environmental protection back cover closed

(6)

(13)

(12)

(11)

(10)

(9)

(14)

(8)

Option function board installed

Environmental protection back cover opened

No

Name

Specifications

(1)

Hook for mounting a

neck strap

Hook for mounting a neck strap (must be prepared by

the user)

(2)

Hook for hanging on

walls

Hook when the Handy GOT is used hanging on walls. 

(3)

E n v i r o n m e n t a l

p r o t e c t i o n   b a c k

cover screw

For opening and closing the environmental protection

back cover (drop prevention screw)

(4)

E n v i r o n m e n t a l

p r o t e c t i o n   b a c k

cover

Opened and closed when the PLC communication
type is changed (RS-422

RS-232, before shipping:

RS-422), the option function board is mounted, or the

battery is replaced.

(5)

Hand strap

Used to hold the Handy GOT in hand by putting a

hand under the strap. Length adjustable.

(6)

Rating plate

Model, consumption current, serial No., Hardware/

Firmware version is indicated.

(7)

Grip switch

Switch for external direct wiring (independent contact)

No

Name

Specifications

(8)

Battery holder

GT11-50BAT type battery holder

(9)

Battery

GT11-50BAT type battery. For storing clock data,

alarm history and recipe data.

(10) C o n n e c t o r   f o r

battery connection

For GT11-50BAT type battery connection

(11) RS-232 interface

Connector for PLC communication using RS-232

(12) Cable connector for

PLC communication

Interface cable connector for PLC communication

Connector for either (11) or (13) and for selection of

the PLC communication type. (Connected to RS-422

before shipping.)

(13) RS-422 interface

Connector for PLC communication using RS-422

(14)

Connector for option

function board

Connector for mounting the GT11-50FNB type option

function board

Item

Specifications

Operating ambient 

temperature

Display section

0 to 40

C

Other than Display section 0 to 40

C

Storage ambient temperature

-20 to 60

C

Operating ambient humidity

10 to 90% RH, non-condensing (The wet bulb temperature is 39

C or less.)

Storage ambient humidity

10 to 90% RH, non-condensing (The wet bulb temperature is 39

C or less.)

Vibration resistance

Conforms to JIS 

B3502 and 

IEC61131-2

Frequency

Acceleration

Half-amplitude

Sweep Count

Under intermittent

vibration

5 to 9Hz

--

3.5mm

10 times each in X, 

Y and Z directions

9 to 150Hz

9.8m/s

2

--

Under continuous

vibration

5 to 9Hz

--

1.75mm

9 to 150Hz

4.9m/s

2

--

Shock resistance

Conforms to JIS B3502, IEC 61131-2 (147 m/s

2

, 3 times each in X, Y and Z directions)

Operating atmosphere

Must be free of lamp black, corrosive gas, flammable gas, or excessive amount of electro conductive dust particles and

must be no direct sunlight. (Same as for saving)

Operating altitude

*1

2000 m (6562 ft) max.

Overvoltage category

*2



 or less

Pollution degree

*3

2 or less

Cooling method

Self-cooling

GT1155HS-QSBD, GT1150HS-QLBD

GT11 Handy GOT General Description

This manual describes the part names, dimensions, mounting, and specifications
of the product. Before use, read this manual and manuals of relevant products
fully to acquire proficiency in handling and operating the product. Make sure to
learn all the product information, safety information, and precautions.
And, store this manual in a safe place so that you can take it out and read it
whenever necessary. Always forward it to the end user.
Registration
The company name and the product name to be described in this manual are the
registered trademarks or trademarks of each company.

Effective Oct. 2016
Specifications are subject to change without notice.

 2008 MITSUBISHI ELECTRIC CORPORATION

Manual Number

JY997D22801L

Date

Oct. 2016

Summary of Contents for GT1155HS-QSBD

Page 1: ...ls of the battery directive in EU member states refer GOT User s Manual TRANSPORTATION PRECAUTIONS When transporting lithium batteries make sure to treat them based on the transport regulations Refer to User s Manual for details of the regurated models Before transporting the GOT turn the GOT power on and check that the battery voltage status is normal on the Time setting display screen utilities ...

Page 2: ...ls of the battery directive in EU member states refer GOT User s Manual TRANSPORTATION PRECAUTIONS When transporting lithium batteries make sure to treat them based on the transport regulations Refer to User s Manual for details of the regurated models Before transporting the GOT turn the GOT power on and check that the battery voltage status is normal on the Time setting display screen utilities ...

Page 3: ...duct may not be used in environments under exposition of oil or chemicals for a long period of time or in environments filled with oil mist 3 3 Power Supply Specifications 1 The GOT continues to operate even upon 5ms or shorter instantaneous power failure The GOT stops operating if there is extended power failure or voltage drop while it automatically resumes operation as soon as the power is rest...

Page 4: ...duct may not be used in environments under exposition of oil or chemicals for a long period of time or in environments filled with oil mist 3 3 Power Supply Specifications 1 The GOT continues to operate even upon 5ms or shorter instantaneous power failure The GOT stops operating if there is extended power failure or voltage drop while it automatically resumes operation as soon as the power is rest...

Page 5: ...ls of the battery directive in EU member states refer GOT User s Manual TRANSPORTATION PRECAUTIONS When transporting lithium batteries make sure to treat them based on the transport regulations Refer to User s Manual for details of the regurated models Before transporting the GOT turn the GOT power on and check that the battery voltage status is normal on the Time setting display screen utilities ...

Page 6: ...duct may not be used in environments under exposition of oil or chemicals for a long period of time or in environments filled with oil mist 3 3 Power Supply Specifications 1 The GOT continues to operate even upon 5ms or shorter instantaneous power failure The GOT stops operating if there is extended power failure or voltage drop while it automatically resumes operation as soon as the power is rest...

Reviews: