52. CONNECTION TO AZBIL CONTROL EQUIPMENT
52.5 Control Equipment Side Setting
52 - 21
52
CONN
ECTI
ON T
O
AZB
IL CONTR
O
L
E
Q
UI
PM
EN
T
53
CONNECTION T
O
RKC T
E
MPERA
T
URE
CONTROLL
ER
54
CONNECTION T
O
A
LL
E
N
-BR
AD
L
E
Y
PL
C
55
CONNE
C
T
ION T
O
GE
P
L
C
56
CON
N
E
C
T
ION T
O
LS
INDUSTRIA
L
S
YSTEMS
P
LC
57
CONNECTION
T
O
SI
CK SAFETY
CONT
ROLLER
58
C
O
NNECTION T
O
SIE
M
ENS PLC
59
CO
N
N
EC
TI
O
N
T
O
HI
RA
TA
C
O
RPO
R
AT
IO
N
HN
C CO
N
TRO
LLER
52.5.6 Connecting to DMC50
Communication settings
Make the communication settings by operating the
Smart Loader Package (SLP-D50/SLP-H21)of the
temperature controller.
*1
Adjust the settings with GOT settings.
*2
Set the module address using the rotary switch for module
address.
*3
Do not set to "0".
*4
Select the module address without overlapping with that of
other units.
Module address setting
Set the module address using the rotary switch for
module address.
52.5.7 Connecting to SDC45/46
Communication settings
Make the communication settings by operating the
Smart Loader Package (SLP-C45) of the temperature
controller.
*1
Adjust the settings with GOT settings.
*2
Set to CPL.
*3
Do not set to "0".
*4
Select the station address without overlapping with that of
other units.
*5
When using the interface converter CMC10L, set the
communication minimum response time to 3ms or more.
52.5.8 Connecting to CMS, CMF015
Communication settings
Make the communication settings by operating the key
of the control equipment.
*1
Adjust the settings with GOT settings.
*2
Do not set to "0".
*3
Select the station address without overlapping with that of
other units.
52.5.9 Connecting to CML, CMF050
Communication settings
Make the communication settings by operating the key
of the control equipment.
*1
Adjust the settings with GOT settings.
*2
Do not set to "0".
*3
Select the station address without overlapping with that of
other units.
52.5.10 Connecting to MQV
Communication settings
Make the communication settings by operating the key
of the control equipment.
*1
Adjust the settings with GOT settings.
*2
Do not set to "0".
*3
Select the station address without overlapping with that of
other units.
Item
Set value
Transmission speed
*1
9600bps, 19200bps, 38400bps
Communication mode
CPL
Data bit
8bits (fixed)
Parity bit
*1
Even (fixed)
Stop bit
1bits (fixed)
Module address
*2*3*4
0 to F
Item
Set value
Transmission speed
*1
9600bps, 19200bps, 38400bps
Communication mode
*2
CPL
Data bit
7bits, 8bits
Parity bit
*1
Odd, even, none
Stop bit
1bit, 2bits
Communication minimum
response time
*5
1 to 250ms
Station address
*3*4
0 to 120
Rotary switch for the module address
01
234
567
89
AB
CDEF
Item
Set value
Transmission speed
*1
9600bps
Communication condition
selection
0: 8-bit data length, Even parity, Stop bit 1
1: 8-bit data length, Non parity, Stop bit 2
Station address
*2*3
0 to 99
Item
Set value
Transmission speed
*1
9600bps
Communication condition
selection
*1
00: 8-bit data length, Even parity, Stop bit 1
01: 8-bit data length, Non parity, Stop bit 2
Station address
*2*3
0 to 7F
Item
Set value
Transmission speed
*1
9600bps, 19200bps, 38400bps
Communication condition
selection
*1
00: 8-bit data length, Even parity, Stop bit 1
01: 8-bit data length, Non parity, Stop bit 2
Station address
*2*3
0 to 127
Summary of Contents for GT16
Page 1: ......
Page 2: ......
Page 46: ...1 4 1 OVERVIEW 1 1 Features ...
Page 54: ...2 8 2 SYSTEM CONFIGURATION 2 2 System Equipment ...
Page 60: ...3 6 3 SPECIFICATIONS 3 4 Battery specifications ...
Page 72: ...5 8 5 UL cUL STANDARDS AND EMC DIRECTIVE 5 2 EMC Directive ...
Page 102: ...6 30 6 OPTION 6 7 Connector Conversion Box ...
Page 106: ...7 4 7 INSTALLATION 7 1 Installing Procedure ...
Page 110: ...8 4 8 COMMUNICATION CABLE 8 1 Overview of Communication Cable ...
Page 130: ...9 20 9 HANDLING OF POWER WIRING AND SWITCH 9 4 Switch Wiring ...
Page 142: ...10 12 10 UTILITY FUNCTION 10 3 Utility Display ...
Page 184: ...11 42 11 DISPLAY AND OPERATION SETTINGS GOT SET UP 11 4 Maintenance Function ...
Page 202: ...12 18 12 COMMUNICATION INTERFACE SETTING COMMUNICATION SETTING 12 3 Ethernet Setting ...
Page 226: ...13 24 13 DEBUG 13 3 Memory Data Control ...
Page 248: ...14 22 14 SELF CHECK 14 2 Batch Self Check ...
Page 350: ...15 102 15 DATA CONTROL 15 3 OS Project Information ...
Page 410: ...19 22 19 TROUBLESHOOTING 19 2 Error Message and System Alarm ...
Page 418: ...App 8 APPENDICES Appendix 3 Transportation Precautions ...
Page 422: ...REVISIONS 4 ...
Page 425: ......
Page 426: ......
Page 427: ......
Page 428: ......
Page 470: ......
Page 510: ...21 22 21 COMPUTER LINK CONNECTION 21 6 Precautions ...
Page 568: ...22 58 22 ETHERNET CONNECTION 22 5 Precautions ...
Page 584: ......
Page 626: ...25 14 25 SERVO AMPLIFIER CONNECTION 25 7 Precautions ...
Page 632: ...26 6 26 ROBOT CONTROLLER CONNECTION 26 6 Precautions ...
Page 647: ...MULTIPLE GOT CONNECTIONS 29 GOT MULTI DROP CONNECTION 29 1 ...
Page 648: ......
Page 659: ...MULTI CHANNEL FUNCTION 30 MULTI CHANNEL FUNCTION 30 1 ...
Page 660: ......
Page 675: ...FA TRANSPARENT FUNCTION 31 FA TRANSPARENT FUNCTION 31 1 ...
Page 676: ......
Page 742: ...31 66 31 FA TRANSPARENT FUNCTION 31 7 Precautions ...
Page 744: ......
Page 766: ...32 22 32 CONNECTION TO IAI ROBOT CONTROLLER 32 7 Precautions ...
Page 802: ...34 10 34 CONNECTION TO OMRON TEMPERATURE CONTROLLER 34 7 Precautions ...
Page 834: ...36 18 36 CONNECTION TO KOYO EI PLC 36 6 Device Range that Can Be Set ...
Page 858: ...38 12 38 CONNECTION TO SHARP PLC 38 6 Device Range that Can Be Set ...
Page 868: ...39 10 39 CONNECTION TO SHINKO TECHNOS INDICATING CONTROLLER 39 7 Precautions ...
Page 902: ...42 6 42 CONNECTION TO TOSHIBA MACHINE PLC 42 6 Device Range that Can Be Set ...
Page 908: ...43 6 43 CONNECTION TO PANASONIC SERVO AMPLIFIER 43 7 Precautions ...
Page 970: ...48 12 48 CONNECTION TO FUJI TEMPERATURE CONTROLLER 48 7 Precautions ...
Page 1052: ...52 26 52 CONNECTION TO AZBIL CONTROL EQUIPMENT 52 7 Precautions ...
Page 1102: ...55 14 55 CONNECTION TO GE PLC 55 7 Precautions ...
Page 1114: ...57 4 57 CONNECTION TO SICK SAFETY CONTROLLER 57 5 Device Range that Can Be Set ...
Page 1128: ...59 2 59 CONNECTION TO HIRATA CORPORATION HNC CONTROLLER ...
Page 1130: ...60 2 60 CONNECTION TO MURATEC CONTROLLER ...
Page 1132: ......
Page 1270: ...62 68 62 MICROCOMPUTER CONNECTION ETHERNET 62 8 Precautions ...
Page 1271: ...MODBUS CONNECTIONS 63 MODBUS R RTU CONNECTION 63 1 64 MODBUS R TCP CONNECTION 64 1 ...
Page 1272: ......
Page 1292: ...64 12 64 MODBUS R TCP CONNECTION 64 7 Precautions ...
Page 1293: ...CONNECTIONS TO PERIPHERAL EQUIPMENT 65 VNC R SERVER CONNECTION 65 1 ...
Page 1294: ......
Page 1298: ...65 4 65 VNC R SERVER CONNECTION 65 4 Setting in Personal Computer ...
Page 1302: ...REVISIONS 4 ...
Page 1305: ......
Page 1306: ......