53. CONNECTION TO RKC TEMPERATURE CONTROLLER
53.5 Temperature Controller Side Setting
53 - 19
52
CONN
ECTI
ON T
O
AZB
IL CONTR
O
L
E
Q
UI
PM
EN
T
53
CONNECTION T
O
RKC T
E
MPERA
T
URE
CONTROLL
ER
54
CONNECTION T
O
A
LL
E
N
-BR
AD
L
E
Y
PL
C
55
CONNE
C
T
ION T
O
GE
P
L
C
56
CON
N
E
C
T
ION T
O
LS
INDUSTRIA
L
S
YSTEMS
P
LC
57
CONNECTION
T
O
SI
CK SAFETY
CONT
ROLLER
58
C
O
NNECTION T
O
SIE
M
ENS PLC
59
CO
N
N
EC
TI
O
N
T
O
HI
RA
TA
C
O
RPO
R
AT
IO
N
HN
C CO
N
TRO
LLER
Unit address settings
Set the unit address using the unit address setting
switch.
Interval time settings
Configure the interval time setting using the RKC
communication setting tool (WinPCI).
After the communication is started, set as follows.
53.5.5 Connecting to CB Series
Communication settings
*1
When the setting value is set to 0, a communication is not
made.
*2
Adjust the settings with GOT settings.
Communication setting mode
Set the communication setting mode using the
operation panel of the CB series main unit.
For details of the communication setting mode, refer to
the following.
CB series "Communication Instruction Manual"
53.5.6 Connecting to FB Series
Communication settings
*1
Items and setting range are common to communication 1
and communication 2.
*2
When the setting value is set to 0, a communication is not
made.
*3
Adjust the settings with GOT settings.
Data bit configuration
Communication setting mode
Set the communication setting mode using the
operation panel of the FB series main unit.
For details of the communication setting mode, refer to
the following.
FB series "Communication Instruction Manual"
Setting Item
Set value
Instrument
0
CFG file
ZCOM_rkc.cfg
Communication 1 interval
time
0 to 250ms
Communication 2 interval
time
Item
Setting range
Device address
*1
1 to 99
Communication speed
*2
2: 9600bps
3: 19200bps
Data bit configuration
0: 8/1/None
6: 8/1/Even
7: 8/1/Odd
Interval time
0 to 150
Unit address setting switch
Setting range : 0 to F
COM
Item
*1
Setting range
*1
Communication protocol
1: MODBUS
Device address
(Slave address)
*2
1 to 99
Communication speed
*3
9.6: 9600bps
19.2: 19200bps
38.4: 38400bps
Data bit configuration
Refer to
■
Interval time
0 to 250
Set value
Data bit
Parity bit
Stop bit
8n1
8
None
1
8n2
8
None
2
8E1
8
Even
1
8E2
8
Even
2
8o1
8
Odd
1
8o2
8
Odd
2
Summary of Contents for GT16
Page 1: ......
Page 2: ......
Page 46: ...1 4 1 OVERVIEW 1 1 Features ...
Page 54: ...2 8 2 SYSTEM CONFIGURATION 2 2 System Equipment ...
Page 60: ...3 6 3 SPECIFICATIONS 3 4 Battery specifications ...
Page 72: ...5 8 5 UL cUL STANDARDS AND EMC DIRECTIVE 5 2 EMC Directive ...
Page 102: ...6 30 6 OPTION 6 7 Connector Conversion Box ...
Page 106: ...7 4 7 INSTALLATION 7 1 Installing Procedure ...
Page 110: ...8 4 8 COMMUNICATION CABLE 8 1 Overview of Communication Cable ...
Page 130: ...9 20 9 HANDLING OF POWER WIRING AND SWITCH 9 4 Switch Wiring ...
Page 142: ...10 12 10 UTILITY FUNCTION 10 3 Utility Display ...
Page 184: ...11 42 11 DISPLAY AND OPERATION SETTINGS GOT SET UP 11 4 Maintenance Function ...
Page 202: ...12 18 12 COMMUNICATION INTERFACE SETTING COMMUNICATION SETTING 12 3 Ethernet Setting ...
Page 226: ...13 24 13 DEBUG 13 3 Memory Data Control ...
Page 248: ...14 22 14 SELF CHECK 14 2 Batch Self Check ...
Page 350: ...15 102 15 DATA CONTROL 15 3 OS Project Information ...
Page 410: ...19 22 19 TROUBLESHOOTING 19 2 Error Message and System Alarm ...
Page 418: ...App 8 APPENDICES Appendix 3 Transportation Precautions ...
Page 422: ...REVISIONS 4 ...
Page 425: ......
Page 426: ......
Page 427: ......
Page 428: ......
Page 470: ......
Page 510: ...21 22 21 COMPUTER LINK CONNECTION 21 6 Precautions ...
Page 568: ...22 58 22 ETHERNET CONNECTION 22 5 Precautions ...
Page 584: ......
Page 626: ...25 14 25 SERVO AMPLIFIER CONNECTION 25 7 Precautions ...
Page 632: ...26 6 26 ROBOT CONTROLLER CONNECTION 26 6 Precautions ...
Page 647: ...MULTIPLE GOT CONNECTIONS 29 GOT MULTI DROP CONNECTION 29 1 ...
Page 648: ......
Page 659: ...MULTI CHANNEL FUNCTION 30 MULTI CHANNEL FUNCTION 30 1 ...
Page 660: ......
Page 675: ...FA TRANSPARENT FUNCTION 31 FA TRANSPARENT FUNCTION 31 1 ...
Page 676: ......
Page 742: ...31 66 31 FA TRANSPARENT FUNCTION 31 7 Precautions ...
Page 744: ......
Page 766: ...32 22 32 CONNECTION TO IAI ROBOT CONTROLLER 32 7 Precautions ...
Page 802: ...34 10 34 CONNECTION TO OMRON TEMPERATURE CONTROLLER 34 7 Precautions ...
Page 834: ...36 18 36 CONNECTION TO KOYO EI PLC 36 6 Device Range that Can Be Set ...
Page 858: ...38 12 38 CONNECTION TO SHARP PLC 38 6 Device Range that Can Be Set ...
Page 868: ...39 10 39 CONNECTION TO SHINKO TECHNOS INDICATING CONTROLLER 39 7 Precautions ...
Page 902: ...42 6 42 CONNECTION TO TOSHIBA MACHINE PLC 42 6 Device Range that Can Be Set ...
Page 908: ...43 6 43 CONNECTION TO PANASONIC SERVO AMPLIFIER 43 7 Precautions ...
Page 970: ...48 12 48 CONNECTION TO FUJI TEMPERATURE CONTROLLER 48 7 Precautions ...
Page 1052: ...52 26 52 CONNECTION TO AZBIL CONTROL EQUIPMENT 52 7 Precautions ...
Page 1102: ...55 14 55 CONNECTION TO GE PLC 55 7 Precautions ...
Page 1114: ...57 4 57 CONNECTION TO SICK SAFETY CONTROLLER 57 5 Device Range that Can Be Set ...
Page 1128: ...59 2 59 CONNECTION TO HIRATA CORPORATION HNC CONTROLLER ...
Page 1130: ...60 2 60 CONNECTION TO MURATEC CONTROLLER ...
Page 1132: ......
Page 1270: ...62 68 62 MICROCOMPUTER CONNECTION ETHERNET 62 8 Precautions ...
Page 1271: ...MODBUS CONNECTIONS 63 MODBUS R RTU CONNECTION 63 1 64 MODBUS R TCP CONNECTION 64 1 ...
Page 1272: ......
Page 1292: ...64 12 64 MODBUS R TCP CONNECTION 64 7 Precautions ...
Page 1293: ...CONNECTIONS TO PERIPHERAL EQUIPMENT 65 VNC R SERVER CONNECTION 65 1 ...
Page 1294: ......
Page 1298: ...65 4 65 VNC R SERVER CONNECTION 65 4 Setting in Personal Computer ...
Page 1302: ...REVISIONS 4 ...
Page 1305: ......
Page 1306: ......