52. CONNECTION TO AZBIL CONTROL EQUIPMENT
52.3 Connection diagram
52 - 15
52
CONN
ECTI
ON T
O
AZB
IL CONTR
O
L
E
Q
UI
PM
EN
T
53
CONNECTION T
O
RKC T
E
MPERA
T
URE
CONTROLL
ER
54
CONNECTION T
O
A
LL
E
N
-BR
AD
L
E
Y
PL
C
55
CONNE
C
T
ION T
O
GE
P
L
C
56
CON
N
E
C
T
ION T
O
LS
INDUSTRIA
L
S
YSTEMS
P
LC
57
CONNECTION
T
O
SI
CK SAFETY
CONT
ROLLER
58
C
O
NNECTION T
O
SIE
M
ENS PLC
59
CO
N
N
EC
TI
O
N
T
O
HI
RA
TA
C
O
RPO
R
AT
IO
N
HN
C CO
N
TRO
LLER
RS485 connection diagram 3)
*1
Pin No. of control equipment differs depending on model or optional function model.
Refer to the following table. The numbers in ( ) of the following table correspond to optional function models.
*2
Terminating resistor should be provided for a control equipment which will be a terminal.
*3
Set the terminating resistor setting switch of the GOT main unit to "Enable".
*4
Connect FG grounding to the single-sided end of a cable shield line.
RS485 connection diagram 4)
*1
Terminating resistor should be provided for a temperature controller which will be a terminal.
*2
Set the terminating resistor setting switch of the GOT main unit to "Enable".
*3
Connect FG grounding to the single-sided end of a cable shield line.
Connector conversion
box
side
*3
Control equipment
side
Control equipment
side
SDA
SDB
RDA
RDB
SG
RSA
CSA
RSB
CSB
FG
RDA
RDB
SDA
SDB
SG
FG
1
6
2
7
5
3
4
8
9
RDA
RDB
SDA
SDB
SG
FG
*4
*4
*1
*1
Terminating resistor(150
Ω
1/2W)*2
Signal name
Model of control equipment
SDC20
SDC21
SDC30
SDC31
SDC40A/40B/40G
(02, 04)
(09)
(03, 06,
08)
(040, 041)
(045)
(446, 546)
Pin No.
Pin No.
Pin No.
Pin No.
Pin No.
Pin No.
Pin No.
RDA
17
18
27
18
18
27
59
RDB
18
19
28
19
19
28
60
SDA
15
16
25
16
16
25
57
SDB
16
17
26
17
17
26
58
SG
5
5
29
5
5
29
61
FG
3, 4
3, 4
3, 4
3, 4
3, 4
3, 4
3
Signal name
Model of control equipment
CMF050
CML
PBC201-VN2
CMC10B
AHC2001
SCU module
Pin No.
Pin No.
Pin No.
Pin No.
RDA
7
14
13
3
RDB
8
15
14
2
SDA
9
12
11
5
SDB
10
13
12
4
SG
12
16
15
1
FG
19
3
-
-
Connector conversion
box side
*2
Temperature controller side
RS-485 terminal (port 1)
Temperature controller side
RS-485 terminal (port 1)
SDA
SDB
RDA
RDB
SG
RSA
CSA
RSB
CSB
RDA1
RDB1
SDA1
SDB1
SG1
1
6
2
7
5
3
4
8
9
6
7
4
5
8
6
7
4
5
8
*3
*3
RDA1
RDB1
SDA1
SDB1
SG1
Terminating resistor (150
Ω
1/2W)
*1
Summary of Contents for GT16
Page 1: ......
Page 2: ......
Page 46: ...1 4 1 OVERVIEW 1 1 Features ...
Page 54: ...2 8 2 SYSTEM CONFIGURATION 2 2 System Equipment ...
Page 60: ...3 6 3 SPECIFICATIONS 3 4 Battery specifications ...
Page 72: ...5 8 5 UL cUL STANDARDS AND EMC DIRECTIVE 5 2 EMC Directive ...
Page 102: ...6 30 6 OPTION 6 7 Connector Conversion Box ...
Page 106: ...7 4 7 INSTALLATION 7 1 Installing Procedure ...
Page 110: ...8 4 8 COMMUNICATION CABLE 8 1 Overview of Communication Cable ...
Page 130: ...9 20 9 HANDLING OF POWER WIRING AND SWITCH 9 4 Switch Wiring ...
Page 142: ...10 12 10 UTILITY FUNCTION 10 3 Utility Display ...
Page 184: ...11 42 11 DISPLAY AND OPERATION SETTINGS GOT SET UP 11 4 Maintenance Function ...
Page 202: ...12 18 12 COMMUNICATION INTERFACE SETTING COMMUNICATION SETTING 12 3 Ethernet Setting ...
Page 226: ...13 24 13 DEBUG 13 3 Memory Data Control ...
Page 248: ...14 22 14 SELF CHECK 14 2 Batch Self Check ...
Page 350: ...15 102 15 DATA CONTROL 15 3 OS Project Information ...
Page 410: ...19 22 19 TROUBLESHOOTING 19 2 Error Message and System Alarm ...
Page 418: ...App 8 APPENDICES Appendix 3 Transportation Precautions ...
Page 422: ...REVISIONS 4 ...
Page 425: ......
Page 426: ......
Page 427: ......
Page 428: ......
Page 470: ......
Page 510: ...21 22 21 COMPUTER LINK CONNECTION 21 6 Precautions ...
Page 568: ...22 58 22 ETHERNET CONNECTION 22 5 Precautions ...
Page 584: ......
Page 626: ...25 14 25 SERVO AMPLIFIER CONNECTION 25 7 Precautions ...
Page 632: ...26 6 26 ROBOT CONTROLLER CONNECTION 26 6 Precautions ...
Page 647: ...MULTIPLE GOT CONNECTIONS 29 GOT MULTI DROP CONNECTION 29 1 ...
Page 648: ......
Page 659: ...MULTI CHANNEL FUNCTION 30 MULTI CHANNEL FUNCTION 30 1 ...
Page 660: ......
Page 675: ...FA TRANSPARENT FUNCTION 31 FA TRANSPARENT FUNCTION 31 1 ...
Page 676: ......
Page 742: ...31 66 31 FA TRANSPARENT FUNCTION 31 7 Precautions ...
Page 744: ......
Page 766: ...32 22 32 CONNECTION TO IAI ROBOT CONTROLLER 32 7 Precautions ...
Page 802: ...34 10 34 CONNECTION TO OMRON TEMPERATURE CONTROLLER 34 7 Precautions ...
Page 834: ...36 18 36 CONNECTION TO KOYO EI PLC 36 6 Device Range that Can Be Set ...
Page 858: ...38 12 38 CONNECTION TO SHARP PLC 38 6 Device Range that Can Be Set ...
Page 868: ...39 10 39 CONNECTION TO SHINKO TECHNOS INDICATING CONTROLLER 39 7 Precautions ...
Page 902: ...42 6 42 CONNECTION TO TOSHIBA MACHINE PLC 42 6 Device Range that Can Be Set ...
Page 908: ...43 6 43 CONNECTION TO PANASONIC SERVO AMPLIFIER 43 7 Precautions ...
Page 970: ...48 12 48 CONNECTION TO FUJI TEMPERATURE CONTROLLER 48 7 Precautions ...
Page 1052: ...52 26 52 CONNECTION TO AZBIL CONTROL EQUIPMENT 52 7 Precautions ...
Page 1102: ...55 14 55 CONNECTION TO GE PLC 55 7 Precautions ...
Page 1114: ...57 4 57 CONNECTION TO SICK SAFETY CONTROLLER 57 5 Device Range that Can Be Set ...
Page 1128: ...59 2 59 CONNECTION TO HIRATA CORPORATION HNC CONTROLLER ...
Page 1130: ...60 2 60 CONNECTION TO MURATEC CONTROLLER ...
Page 1132: ......
Page 1270: ...62 68 62 MICROCOMPUTER CONNECTION ETHERNET 62 8 Precautions ...
Page 1271: ...MODBUS CONNECTIONS 63 MODBUS R RTU CONNECTION 63 1 64 MODBUS R TCP CONNECTION 64 1 ...
Page 1272: ......
Page 1292: ...64 12 64 MODBUS R TCP CONNECTION 64 7 Precautions ...
Page 1293: ...CONNECTIONS TO PERIPHERAL EQUIPMENT 65 VNC R SERVER CONNECTION 65 1 ...
Page 1294: ......
Page 1298: ...65 4 65 VNC R SERVER CONNECTION 65 4 Setting in Personal Computer ...
Page 1302: ...REVISIONS 4 ...
Page 1305: ......
Page 1306: ......