M70V Series Connection Manual
4.2 Connection of Control Unit
109
4.2.5.2 Connecting with MDS-DM2 Series
(1) When using only MDS-DM2-SPV Series
(2) When using the MDS-D2 unit together
CAUTION
1.Connect the NC and the drive units by the optical communication cables. The distance between the NC and the
final drive unit must be within 30m and the bending radius within 80mm.
2.A spindle drive unit that controls the high-speed synchronous tapping (OMR-DD control) has to be connected
on the farther side from the NC than the subject synchronous tapping control.
Thus, if you use an MDS-DM2 unit for servo control of the high-speed synchronous tapping, combinable
spindle drive is that of the MDS-DM2 unit only.
POINT
For MDS-DM2-SPV Series, axis Nos. are fixed as follows.
1st axis : spindle
2nd axis : servo L axis
3rd axis : servo M axis
4th axis : servo axis (only MDS-DM2-SPV3)
MDS-DM2-SPV3
Spindle:1st axis
Servo:2nd/3rd/4th axis
to the NC
Connected
communication
Optical
cable
CN4
MDS-D2-V2
MDS-D2-SP
MDS-DM2-SPV3
MDS-D2-CV
CN4
Connected
to the NC
Optical
communication
cable
The optical communication cables from the NC to the
final drive unit must be within 30m.
5th/6th axis
7th axis
(Final axis)
Servo:2nd/3rd/4th axis
Spindle:1st axis
Summary of Contents for M70V Series
Page 1: ......
Page 13: ......
Page 15: ......
Page 17: ......
Page 19: ......
Page 21: ......
Page 25: ......
Page 26: ...1 1 System Configuration ...
Page 36: ...11 2 General Specifications ...
Page 110: ...85 3 Installation ...
Page 120: ...95 4 Connection ...
Page 173: ...4 Connection MITSUBISHI CNC 148 ...
Page 174: ...149 付録 Ap 1 章 149 Appendix 1 Cable ...
Page 220: ...195 付録 Ap 2 章 195 Appendix 2 EMC Installation Guidelines ...
Page 232: ...207 付録 Ap 3 章 207 Appendix 3 Restrictions for Lithium Batteries ...
Page 241: ...Appendix 3 Restrictions for Lithium Batteries MITSUBISHI CNC 216 ...
Page 242: ...217 付録 Ap 4 章 217 Appendix 4 Precautions for Compliance to UL c UL Standards ...
Page 246: ......
Page 250: ......