4 Connection
MITSUBISHI CNC
128
4.3.4.3 Wiring for Sink Type Output (FCU7-DX710/DX720/DX730)
(Note 1) C24V to either or both of the flat connector 1B, 2B (24VDC). (*1)
(Note 2) Connect 0V (GND) to the flat connector 3A, 3B, 4A, 4B (GND). (*2)
Decide the number of GNDs to wire with regard to the total amount of each connector's maximum output
current and the voltage drop by the cables. The rated current is 1A per connector pin.
(Note 3) Connect 0V (GND) to the flat connector 1A, 2A (GND). (*2)
(Note 4) When large current flows due to small amount of connected load, fuse may be blown out or 24V power supply
voltage may drop. In order to secure the appropriate current value, watch the connected load.
2B
20B
19B
18B
17B
16B
15B
14B
13B
12B
11B
10B
9B
8B
7B
6B
5B
3A
3B
GND
GND
1A
2A
GND
GND
1B
4A
4B
GND
GND
GND
Y200
Y201
Y202
Y203
Y204
Y205
Y206
Y207
Y208
Y209
Y20A
Y20B
Y20C
Y20D
Y20E
Y20F
Y210
Y211
Y212
Y213
Y214
Y215
Y216
Y217
Y218
Y219
Y21A
Y21B
Y21C
Y21D
Y21E
Y21F
20A
19A
18A
17A
16A
15A
14A
13A
12A
11A
10A
9A
8A
7A
6A
5A
CG32 (CG34,CG36)
PL
RA
PL
PL
PL
PL
PL
RA
RA
PL
:
:
24VDC
24VDC
Operation panel I/O unit
(Card name : HN341/HN361/HN362)
Machine side
*1 additional wiring
*2 additional wiring
Output device (Connection example)
24VDC
Relay
Pilot lamp
Summary of Contents for M70V Series
Page 1: ......
Page 13: ......
Page 15: ......
Page 17: ......
Page 19: ......
Page 21: ......
Page 25: ......
Page 26: ...1 1 System Configuration ...
Page 36: ...11 2 General Specifications ...
Page 110: ...85 3 Installation ...
Page 120: ...95 4 Connection ...
Page 173: ...4 Connection MITSUBISHI CNC 148 ...
Page 174: ...149 付録 Ap 1 章 149 Appendix 1 Cable ...
Page 220: ...195 付録 Ap 2 章 195 Appendix 2 EMC Installation Guidelines ...
Page 232: ...207 付録 Ap 3 章 207 Appendix 3 Restrictions for Lithium Batteries ...
Page 241: ...Appendix 3 Restrictions for Lithium Batteries MITSUBISHI CNC 216 ...
Page 242: ...217 付録 Ap 4 章 217 Appendix 4 Precautions for Compliance to UL c UL Standards ...
Page 246: ......
Page 250: ......