M70V Series Connection Manual
4.5 Connection of MITSUBISHI CNC Machine Operation Panel
145
<Software Interface>
Machine operation panel occupies RIO station No. 4 to 6. The device numbers for switch and LED on operation
panel are fixed as listed below.
The following lists the devices for using the RIO 1st channel.
Table: Device No. for Machine operation panel
(1) Machine operation panel B (Switch)
Machine operation panel B is equipped with rotary switches (cutting override, spindle override) and a selector
switch (memory protection key), and an emergency stop button. Direct wiring connection will be applied to the
emergency stop button, and device numbers for other switches are defined as listed below.
(a) Cutting override (6bit)
21 position code list
Station
Device No.
Detail
RIO1
RIO3
1
X00
~
X1F/Y00
~
Y1F
X200
~
X21F/Y200
~
Y21F
2
X20
~
X3F/Y20
~
Y3F
X220
~
X23F/Y220
~
Y23F
3
X40
~
X5F/Y40
~
Y5F
X240
~
X25F/Y240
~
Y25F
4
X60
~
X7F/Y60
~
Y7F
X260
~
X27F/Y260
~
Y27F
Machine operation panel B
(Switch)...16 points vacant
5
X80
~
X9F/Y80
~
Y9F
X280
~
X29F/Y280
~
Y29F
Machine operation panel A
(Key switch/LED)
6
XA0
~
XBF/YA0
~
YBF
X2A0
~
X2BF/Y2A0
~
Y2BF
Machine operation panel A
(Key switch/LED)
7
XC0
~
XDF/YC0
~
YDF
-
8
XE0
~
XFF/YE0
~
YFF
-
Device No.
Setting value X60 X61 X62 X63 X64 X65
0
0
0
0
0
0
0
1
1
0
0
0
0
1
2
1
1
0
0
0
0
3
0
1
0
0
0
1
4
0
1
1
0
0
0
5
1
1
1
0
0
1
6
1
0
1
0
0
0
7
0
0
1
0
0
1
8
0
0
1
1
0
0
9
1
0
1
1
0
1
10
1
1
1
1
0
0
11
0
1
1
1
0
1
12
0
1
0
1
0
0
13
1
1
0
1
0
1
14
1
0
0
1
0
0
15
0
0
0
1
0
1
16
0
0
0
1
1
0
17
1
0
0
1
1
1
18
1
1
0
1
1
0
19
0
1
0
1
1
1
20
0
1
1
1
1
0
Summary of Contents for M70V Series
Page 1: ......
Page 13: ......
Page 15: ......
Page 17: ......
Page 19: ......
Page 21: ......
Page 25: ......
Page 26: ...1 1 System Configuration ...
Page 36: ...11 2 General Specifications ...
Page 110: ...85 3 Installation ...
Page 120: ...95 4 Connection ...
Page 173: ...4 Connection MITSUBISHI CNC 148 ...
Page 174: ...149 付録 Ap 1 章 149 Appendix 1 Cable ...
Page 220: ...195 付録 Ap 2 章 195 Appendix 2 EMC Installation Guidelines ...
Page 232: ...207 付録 Ap 3 章 207 Appendix 3 Restrictions for Lithium Batteries ...
Page 241: ...Appendix 3 Restrictions for Lithium Batteries MITSUBISHI CNC 216 ...
Page 242: ...217 付録 Ap 4 章 217 Appendix 4 Precautions for Compliance to UL c UL Standards ...
Page 246: ......
Page 250: ......