2 General Specifications
MITSUBISHI CNC
24
(19) LED
(20) Slide switch
This is for MITSUBISHI exclusive use. Do not change the switch from the condition at the time of shipment from
MITSUBISHI.
MITSUBISHI default settings differ depending on the display size as follows.
Name
Function
At fault
Conditions
24VDCIN
DC24V input check
Not lit
(1) Failure of DC24V input
(2) Fuse is disconnected near DCIN connector
DCOUT
Internal output voltage check Not lit
(1) Failure of internal voltage output in control unit
(2) Short circuit of DC5V output on CG71 or ENC or FAN connector
LCDON
DC12V output voltage check
for backlight inverter or
backlight driver
Not lit
(1) Failure of DC12V output in control unit
(2) 24VDC input voltage is +20V or less
PSEMG
External emergency stop
status display
Lit (Red)
External emergency stop signal has inputted
WDER
System error display
Lit (Red)
(1) Failure of control unit
(2) SRAM data is broken
BATALM
Battery voltage drop
Lit (Red)
Battery voltage has dropped to 2.7V or less
Display size
Slide switch position
8.4-type
Right
10.4-type
Left
Name
Summary of Contents for M70V Series
Page 1: ......
Page 13: ......
Page 15: ......
Page 17: ......
Page 19: ......
Page 21: ......
Page 25: ......
Page 26: ...1 1 System Configuration ...
Page 36: ...11 2 General Specifications ...
Page 110: ...85 3 Installation ...
Page 120: ...95 4 Connection ...
Page 173: ...4 Connection MITSUBISHI CNC 148 ...
Page 174: ...149 付録 Ap 1 章 149 Appendix 1 Cable ...
Page 220: ...195 付録 Ap 2 章 195 Appendix 2 EMC Installation Guidelines ...
Page 232: ...207 付録 Ap 3 章 207 Appendix 3 Restrictions for Lithium Batteries ...
Page 241: ...Appendix 3 Restrictions for Lithium Batteries MITSUBISHI CNC 216 ...
Page 242: ...217 付録 Ap 4 章 217 Appendix 4 Precautions for Compliance to UL c UL Standards ...
Page 246: ......
Page 250: ......