8. Adjustment Procedure
8
−
9
8.5 Orientation adjustment
8.5.1 Motor built-in encoder orientation adjustment preparation
< Parameters >
Parameter name
No.
Initial value
PGM SP001 100
OINP SP004 16
OSP SP005 0
CSP SP006 20
OPST SP007 0
GRA1 SP025 1
GRA2 SP026 1
GRA3 SP027 1
GRA4 SP028 1
GRB1 SP029 1
GRB2 SP030 1
GRB3 SP031 1
GRB4 SP032 1
VGOP SP098 63
VGOI SP099 60
VGOD SP100 15
CSP2 SP107 0
CSP3 SP108 0
CSP4 SP109 0
< Preparation >
a) Check that the parameters are set to the values in the table above.