11. Troubleshooting
11
−
13
(15) Alarm No. 37 : PARAMETER ERROR
[Details]
There were errors in the spindle parameters transmitted from the NC during
initialization.
Investigation items
Investigation results
Remedy
There was an incorrectly set value.
Set the correct value.
1 Check the spindle
parameter setting
values. The No. of the
incorrectly set
parameter is displayed
on the NC
DIAGNOSIS
SCREEN.
No particular problem.
Investigate item 2, and carry out the
appropriate measures.
2 Investigate as in alarm
No. 34 , and carry
out the appropriate
measures.
(16) Alarm No. 38 : NC COMMUNICATION AND PROTOCOL ERROR 1
[Details]
The protocol error "FRAME ERROR" occurred in the communication with the NC.
Investigation items
Investigation results
Remedy
1 Investigate as in alarm
No. 34 , and carry
out the appropriate
measures.
(17) Alarm No. 39 : NC COMMUNICATION AND PROTOCOL ERROR 2
[Details]
The protocol error "INFORMATION ERROR" occurred in the communication with the
NC.
Investigation items
Investigation results
Remedy
1 Investigate as in alarm
No. 34 , and carry
out the appropriate
measures.