MDS-E/EH Series Instruction Manual
4 Setup
115
IB-1501229-F
4.2 Setting the Initial Parameters for the Servo Drive Unit
The servo parameters must be set before the servo system can be started up. The servo parameters are input from the
NC. The input method differs according to the NC being used, so refer to each NC Instruction Manual.
When setting the initial setting parameters, perform the following settings in each system.
<For semi closed loop control (single-axis control)>
(1) Set the standard parameters in the section "4.2.5 List of Standard Parameters for Each Servo Motor".
(2) "4.2.1 Setting of Servo Specification Parameters"
< For full closed loop control (single-axis control) >
(1) Set the standard parameters in the section "4.2.5 List of Standard Parameters for Each Servo Motor".
(2) "4.2.1 Setting of Servo Specification Parameters"
(3) "4.2.2 Setting of Machine Side Encoder"
<For full closed loop control with a distance-coded reference scale (single-axis control)>
(1) Set the standard parameters in the section "4.2.5 List of Standard Parameters for Each Servo Motor".
(2) "4.2.1 Setting of Servo Specification Parameters"
(3) "4.2.2 Setting of Machine Side Encoder"
(4) "4.2.3 Setting of Distance-coded Reference Scale"
< For speed command synchronous control >
(1) Set the standard parameters in the section "4.2.5 List of Standard Parameters for Each Servo Motor".
(2) "4.2.1 Setting of Servo Specification Parameters"
(3) "4.2.2 Setting of Machine Side Encoder"
(4) "4.2.4 Setting of Speed Command Synchronous Control"
(Note)
For the position command synchronous control, perform the items of single-axis control for each axis.
Setting the initial parameters above enables the test operation for the servo axis (Ex. manual pulse feed, low-speed JOG
feed). When machine resonance occurs, check the machine resonance frequency at AFLT frequency on the drive
monitor screen and set to the following servo parameters (When the AFLT frequency displays "0", resonance is not
occurring).
【
#2238
】
SV038 FHz1 Notch filter frequency 1
Set the vibration frequency to suppress when machine vibration occurs.
(Normally, do not set 80 or less.)
---Setting range---
0 to 5000 (Hz)
Summary of Contents for MDS-E
Page 1: ......
Page 3: ......
Page 15: ......
Page 17: ......
Page 19: ......
Page 21: ......
Page 31: ......
Page 32: ...1 IB 1501229 F 1 Installation ...
Page 76: ...45 IB 1501229 F 2 Wiring and Connection ...
Page 132: ...101 IB 1501229 F 3 Safety Function ...
Page 142: ...111 IB 1501229 F 4 Setup ...
Page 277: ...MDS E EH Series Instruction Manual 4 Setup 246 IB 1501229 F ...
Page 278: ...247 IB 1501229 F 5 Servo Adjustment ...
Page 351: ...MDS E EH Series Instruction Manual 5 Servo Adjustment 320 IB 1501229 F ...
Page 352: ...321 IB 1501229 F 6 Spindle Adjustment ...
Page 404: ...373 IB 1501229 F 7 Troubleshooting ...
Page 455: ...MDS E EH Series Instruction Manual 7 Troubleshooting 424 IB 1501229 F ...
Page 456: ...425 IB 1501229 F 8 Maintenance ...
Page 475: ...MDS E EH Series Instruction Manual 8 Maintenance 444 IB 1501229 F ...
Page 476: ...445 IB 1501229 F 9 Power Backup System ...
Page 494: ...463 IB 1501229 F 10 Appx 1 Cable and Connector Assembly ...
Page 504: ...473 IB 1501229 F 11 Appx 2 D A Output Specifications for Drive Unit ...
Page 514: ...483 IB 1501229 F 12 Appx 3 Protection Function ...
Page 523: ...MDS E EH Series Instruction Manual 12 Appx 3 Protection Function 492 IB 1501229 F ...
Page 524: ...493 IB 1501229 F 13 Appx 4 Compliance to EC Directives ...
Page 528: ...497 IB 1501229 F 14 Appx 5 EMC Installation Guidelines ...
Page 540: ...509 IB 1501229 F 15 Appx 6 Higher Harmonic Suppression Measure Guidelines ...
Page 550: ......
Page 554: ......