MDS-E/EH Series Instruction Manual
4 Setup
124
IB-1501229-F
4.2.4 Setting of Speed Command Synchronous Control
This section explains about the setting of the speed command synchronous control of the full closed loop control. The
servo parameter setting during the position command synchronous control is same as single axis.
【
#2225(PR)
】
SV025 MTYP Motor/Encoder type
Set the position encoder type for the secondary axis to "D". The same value is set for 2-axis drive
unit, 3-axis drive unit and two 1-axis drive units.
bit F-C : pen Position encoder
Speed command synchronization control primary axis : pen=A
Speed command synchronization control secondary axis : pen=D
CAUTION
1. When performing the speed command synchronous control with 2-axis drive unit (MDS-E/EH-V2), make sure to set L-
axis as primary axis. When performing the speed command synchronous control with 3-axis drive unit (MDS-E-V3),
make sure to set L-axis as primary axis and M-axis as secondary axis.
2. The rectangular waveform output scale is not available for the speed command synchronous control.
3. The distance-coded reference scale is not available for the speed command synchronous control.
4. When using speed command synchronization control, the following setting of NC side is required.
- Set bit3 of #1281:ext17 to "0" and disable the synchronous error automatic correction function at servo ON.
- Set #1064:svof of the primary axis and secondary axis to "0" and disable the error correction at servo OFF for both
axes.
- The parameter settings related to the machine error compensation such as quadrant protrusion compensation must be
the same for the primary axis and secondary axis.
Summary of Contents for MDS-E
Page 1: ......
Page 3: ......
Page 15: ......
Page 17: ......
Page 19: ......
Page 21: ......
Page 31: ......
Page 32: ...1 IB 1501229 F 1 Installation ...
Page 76: ...45 IB 1501229 F 2 Wiring and Connection ...
Page 132: ...101 IB 1501229 F 3 Safety Function ...
Page 142: ...111 IB 1501229 F 4 Setup ...
Page 277: ...MDS E EH Series Instruction Manual 4 Setup 246 IB 1501229 F ...
Page 278: ...247 IB 1501229 F 5 Servo Adjustment ...
Page 351: ...MDS E EH Series Instruction Manual 5 Servo Adjustment 320 IB 1501229 F ...
Page 352: ...321 IB 1501229 F 6 Spindle Adjustment ...
Page 404: ...373 IB 1501229 F 7 Troubleshooting ...
Page 455: ...MDS E EH Series Instruction Manual 7 Troubleshooting 424 IB 1501229 F ...
Page 456: ...425 IB 1501229 F 8 Maintenance ...
Page 475: ...MDS E EH Series Instruction Manual 8 Maintenance 444 IB 1501229 F ...
Page 476: ...445 IB 1501229 F 9 Power Backup System ...
Page 494: ...463 IB 1501229 F 10 Appx 1 Cable and Connector Assembly ...
Page 504: ...473 IB 1501229 F 11 Appx 2 D A Output Specifications for Drive Unit ...
Page 514: ...483 IB 1501229 F 12 Appx 3 Protection Function ...
Page 523: ...MDS E EH Series Instruction Manual 12 Appx 3 Protection Function 492 IB 1501229 F ...
Page 524: ...493 IB 1501229 F 13 Appx 4 Compliance to EC Directives ...
Page 528: ...497 IB 1501229 F 14 Appx 5 EMC Installation Guidelines ...
Page 540: ...509 IB 1501229 F 15 Appx 6 Higher Harmonic Suppression Measure Guidelines ...
Page 550: ......
Page 554: ......