Parameter
200V Standard motor HG Series
HG123
HG223
HG303
HG453
HG703
HG903
HG142
HG302
No.
Abbrev.
Details
MDS-E-V1-
20
-
40
-
80
-
160
160W
320
20
-
40
-
MDS-E-V2-
20
40
40
80
80
160
160,
160W
160W
-
20
40
40
80
MDS-E-V3-
20
40
40
80
80
-
-
-
-
20
40
40
80
SV001
PC1
Motor side gear ratio
-
-
-
-
-
-
-
-
SV002
PC2
Machine side gear ratio
-
-
-
-
-
-
-
-
SV003
PGN1
Position loop gain 1
33
33
33
33
33
33
33
33
SV004
PGN2
Position loop gain 2
0
0
0
0
0
0
0
0
SV005
VGN1
Speed loop gain 1
100
100
100
100
100
100
100
100
SV006
VGN2
Speed loop gain 2
0
0
0
0
0
0
0
0
SV007
VIL
Speed loop delay compensation
0
0
0
0
0
0
0
0
SV008
VIA
Speed loop lead compensation
1364
1364
1364
1364
1364
1364
1364
1364
SV009
IQA
Current loop q axis lead compensation
10240
8192
10240
6144
6144
4096
15360
8192
SV010
IDA
Current loop d axis lead compensation
10240
8192
10240
6144
6144
4096
15360
8192
SV011
IQG
Current loop q axis gain
1536
1280
2048
2048
2048
1536
2048
2048
SV012
IDG
Current loop d axis gain
1536
1280
2048
2048
2048
1536
2048
2048
SV013
ILMT
Current limit value
800
800
800
800
800
800
800
800
SV014 ILMTsp Current limit value in special control
800
800
800
800
800
800
800
800
SV015
FFC
Acceleration rate feed forward gain
0
0
0
0
0
0
0
0
SV016
LMC1
Lost motion compensation 1
0
0
0
0
0
0
0
0
SV017 SPEC1 Servo specification 1
1000 1400 1000 1400 1000 1400
1000
1000
1000 1000 1400 1000 1400
SV018
PIT
Ball screw pitch/Magnetic pole pitch
-
-
-
-
-
-
-
-
SV019
RNG1
Sub side encoder resolution
0
0
0
0
0
0
0
0
SV020
RNG2
Main side encoder resolution
0
0
0
0
0
0
0
0
SV021
OLT
Overload detection time constant
60
60
60
60
60
60
60
60
SV022
OLL
Overload detection level
150
150
150
150
150
150
150
150
SV023
OD1
Excessive error detection width during
servo ON
6
6
6
6
6
6
6
6
SV024
INP
In-position detection width
50
50
50
50
50
50
50
50
SV025
MTYP
Motor/Encoder type
2264
2266
2268
2249
224A
224B
2265
2267
SV026
OD2
Excessive error detection width during
servo OFF
6
6
6
6
6
6
6
6
SV027
SSF1
Servo function 1
4000
4000
4000
4000
4000
4000
4000
4000
SV028
0
0
0
0
0
0
0
0
:
:
:
:
:
:
:
:
:
SV032
TOF
Torque offset
0
0
0
0
0
0
0
0
SV033
SSF2
Servo function 2
0000
0000
0000
0000
0000
0000
0000
0000
SV034
SSF3
Servo function 3
0000
0000
0000
0000
0000
0000
0000
0000
SV035
SSF4
Servo function 4
0000
0000
0000
0000
0000
0000
0000
0000
SV036
PTYP
Power supply type/ Regenerative
resistor type
0000
0000
0000
0000
0000
0000
0000
0000
SV037
JL
Load inertia scale
0
0
0
0
0
0
0
0
:
:
:
:
:
:
:
:
:
SV046
FHz2
Notch filter frequency 2
0
0
0
0
0
0
0
0
SV047
EC
Inductive voltage compensation gain
100
100
100
100
100
100
100
100
SV048 EMGrt Vertical axis drop prevention time
0
0
0
0
0
0
0
0
SV049 PGN1sp
Position loop gain 1 in spindle
synchronous control
15
15
15
15
15
15
15
15
SV050 PGN2sp
Position loop gain 2 in spindle
synchronous control
0
0
0
0
0
0
0
0
:
:
:
:
:
:
:
:
:
SV065
TLC
Machine end compensation gain
0
0
0
0
0
0
0
0
(System parameter area)
SV073 FEEDout Specified speed output speed
0
0
0
0
0
0
0
0
(System parameter area)
SV081 SPEC2 Servo specification 2
0200
0200
0200
0200
0200
0200
0200
0200
SV082
SSF5
Servo function 5
0000
0000
0000
0000
0000
0000
0000
0000
SV083
SSF6
Servo function 6
0000
0000
0000
0000
0000
0000
0000
0000
SV084
SSF7
Servo function 7
0000
0000
0000
0000
0000
0000
0000
0000
SV085
LMCk
Lost motion compensation 3 spring
constant
0
0
0
0
0
0
0
0
:
:
:
:
:
:
:
:
:
SV093
0
0
0
0
0
0
0
0
SV094
MPV
Magnetic pole position error detection
speed
10
10
10
10
10
10
10
10
SV095
ZUPD
Vertical axis pull up distance
0
0
0
0
0
0
0
0
:
:
:
:
:
:
:
:
:
SV113
SSF8
Servo function 8
0
0
0
0
0
0
0
0
SV114
SSF9
Servo function 9
0080
0080
0080
0080
0080
0080
0080
0080
SV115 SSF10 Servo function 10
0
0
0
0
0
0
0
0
:
:
:
:
:
:
:
:
:
SV256
0
0
0
0
0
0
0
0
Summary of Contents for MDS-E
Page 1: ......
Page 3: ......
Page 15: ......
Page 17: ......
Page 19: ......
Page 21: ......
Page 31: ......
Page 32: ...1 IB 1501229 F 1 Installation ...
Page 76: ...45 IB 1501229 F 2 Wiring and Connection ...
Page 132: ...101 IB 1501229 F 3 Safety Function ...
Page 142: ...111 IB 1501229 F 4 Setup ...
Page 277: ...MDS E EH Series Instruction Manual 4 Setup 246 IB 1501229 F ...
Page 278: ...247 IB 1501229 F 5 Servo Adjustment ...
Page 351: ...MDS E EH Series Instruction Manual 5 Servo Adjustment 320 IB 1501229 F ...
Page 352: ...321 IB 1501229 F 6 Spindle Adjustment ...
Page 404: ...373 IB 1501229 F 7 Troubleshooting ...
Page 455: ...MDS E EH Series Instruction Manual 7 Troubleshooting 424 IB 1501229 F ...
Page 456: ...425 IB 1501229 F 8 Maintenance ...
Page 475: ...MDS E EH Series Instruction Manual 8 Maintenance 444 IB 1501229 F ...
Page 476: ...445 IB 1501229 F 9 Power Backup System ...
Page 494: ...463 IB 1501229 F 10 Appx 1 Cable and Connector Assembly ...
Page 504: ...473 IB 1501229 F 11 Appx 2 D A Output Specifications for Drive Unit ...
Page 514: ...483 IB 1501229 F 12 Appx 3 Protection Function ...
Page 523: ...MDS E EH Series Instruction Manual 12 Appx 3 Protection Function 492 IB 1501229 F ...
Page 524: ...493 IB 1501229 F 13 Appx 4 Compliance to EC Directives ...
Page 528: ...497 IB 1501229 F 14 Appx 5 EMC Installation Guidelines ...
Page 540: ...509 IB 1501229 F 15 Appx 6 Higher Harmonic Suppression Measure Guidelines ...
Page 550: ......
Page 554: ......