MDS-E/EH Series Instruction Manual
4 Setup
145
IB-1501229-F
MDS-E/EH Series: Power supply type
When connecting a power supply unit, set a code for each power supply unit.
bit F-C : amp
Set the power backup function to be used.
No function used : 0
Deceleration and stop function at power failure : 8
Retraction function at power failure : C
bit B-8 : rtyp
Not used. Set to "0".
bit 7-0 : ptyp External emergency stop setting
When the emergency stop input signal of the power supply unit is "disabled"
Power supply unit is not connected : 00
MDS-E-CV-37 / MDS-EH-CV-37 : 04
MDS-E-CV-75 / MDS-EH-CV-75 : 08
MDS-E-CV-110 / MDS-EH-CV-110 : 11
MDS-E-CV-185 / MDS-EH-CV-185 : 19
MDS-E-CV-300 / MDS-EH-CV-300 : 30
MDS-E-CV-370 / MDS-EH-CV-370 : 37
MDS-E-CV-450 / MDS-EH-CV-450 : 45
MDS-E-CV-550 / MDS-EH-CV-550 : 55
MDS-EH-CV-750 : 75
When the emergency stop input signal of the power supply unit is "enabled"
(Note) Set the power supply rotary switch to "4".
Power supply unit is not connected : 00
MDS-E-CV-37 / MDS-EH-CV-37 : 44
MDS-E-CV-75 / MDS-EH-CV-75 : 48
MDS-E-CV-110 / MDS-EH-CV-110 : 51
MDS-E-CV-185 / MDS-EH-CV-185 : 59
MDS-E-CV-300 / MDS-EH-CV-300 : 70
MDS-E-CV-370 / MDS-EH-CV-370 : 77
MDS-E-CV-450 / MDS-EH-CV-450 : 85
MDS-E-CV-550 / MDS-EH-CV-550 : 95
MDS-EH-CV-750 : B5
MDS-EM/EMH Series
Not used. Set to "0000".
External emergency stop power supply type is set by spindle parameter (SP032).
(PR)
#2236
SV036 PTYP
Power supply type/ Regenerative resistor type
ptyp
rtyp
amp
Summary of Contents for MDS-E
Page 1: ......
Page 3: ......
Page 15: ......
Page 17: ......
Page 19: ......
Page 21: ......
Page 31: ......
Page 32: ...1 IB 1501229 F 1 Installation ...
Page 76: ...45 IB 1501229 F 2 Wiring and Connection ...
Page 132: ...101 IB 1501229 F 3 Safety Function ...
Page 142: ...111 IB 1501229 F 4 Setup ...
Page 277: ...MDS E EH Series Instruction Manual 4 Setup 246 IB 1501229 F ...
Page 278: ...247 IB 1501229 F 5 Servo Adjustment ...
Page 351: ...MDS E EH Series Instruction Manual 5 Servo Adjustment 320 IB 1501229 F ...
Page 352: ...321 IB 1501229 F 6 Spindle Adjustment ...
Page 404: ...373 IB 1501229 F 7 Troubleshooting ...
Page 455: ...MDS E EH Series Instruction Manual 7 Troubleshooting 424 IB 1501229 F ...
Page 456: ...425 IB 1501229 F 8 Maintenance ...
Page 475: ...MDS E EH Series Instruction Manual 8 Maintenance 444 IB 1501229 F ...
Page 476: ...445 IB 1501229 F 9 Power Backup System ...
Page 494: ...463 IB 1501229 F 10 Appx 1 Cable and Connector Assembly ...
Page 504: ...473 IB 1501229 F 11 Appx 2 D A Output Specifications for Drive Unit ...
Page 514: ...483 IB 1501229 F 12 Appx 3 Protection Function ...
Page 523: ...MDS E EH Series Instruction Manual 12 Appx 3 Protection Function 492 IB 1501229 F ...
Page 524: ...493 IB 1501229 F 13 Appx 4 Compliance to EC Directives ...
Page 528: ...497 IB 1501229 F 14 Appx 5 EMC Installation Guidelines ...
Page 540: ...509 IB 1501229 F 15 Appx 6 Higher Harmonic Suppression Measure Guidelines ...
Page 550: ......
Page 554: ......