MDS-E/EH Series Instruction Manual
4 Setup
152
IB-1501229-F
The shape of the machine end is compensated by compensating the spring effect from the machine end to
the motor end.
Set the machine end compensation gain. Measure the error amount by roundness measurement and esti-
mate the setting value by the following formula.
Compensation amount (
μ
m) = Command speed F(mm/min)2 * SV065 / (Radius R(mm) * SV003 *
16,200,000)
Set to "0" when not using.
---Setting range---
-30000 to 30000 (Acceleration ratio 0.1%)
This parameter is set automatically by the NC system.
Set the specified speed.
Also set SV082/bit9,8 to output digital signal.
---Setting range---
0 to 32767 (r/min)
However, when SV033/bitD=1, the setting range is from 0 to 32767 (100mm/min).
(Only for MDS-E/EH and MDS-EM/EMH)
This parameter is set automatically by the NC system.
Select the servo functions.
A function is assigned to each bit.
Set this in hexadecimal format.
bit F-A:
Not used. Set to "0".
bit 9: npg Earth fault detection
0: Disable 1: Enable (standard)
Set "0" and it is constantly "Enable" for MDS-EJ/EJH Series.
bit 8:
Not used. Set to "0".
bit 7: szchk Distance-coded reference scale reference mark
0: Check at 4 points (standard) 1: Check at 3 points
bit 6-4:
Not used. Set to "0".
bit 3: absc Distance-coded reference scale
0: Disable 1: Enable
bit 2-0:
Not used. Set to "0".
#2265
SV065 TLC
Machine end compensation gain
#2266-2272
SV066 - SV072
(PR)
#2273
SV073 FEEDout
Specified speed output speed
#2274-2280
SV074 - SV080
(PR)
#2281
SV081 SPEC2
Servo specification 2
absc
szchk
npg
Summary of Contents for MDS-E
Page 1: ......
Page 3: ......
Page 15: ......
Page 17: ......
Page 19: ......
Page 21: ......
Page 31: ......
Page 32: ...1 IB 1501229 F 1 Installation ...
Page 76: ...45 IB 1501229 F 2 Wiring and Connection ...
Page 132: ...101 IB 1501229 F 3 Safety Function ...
Page 142: ...111 IB 1501229 F 4 Setup ...
Page 277: ...MDS E EH Series Instruction Manual 4 Setup 246 IB 1501229 F ...
Page 278: ...247 IB 1501229 F 5 Servo Adjustment ...
Page 351: ...MDS E EH Series Instruction Manual 5 Servo Adjustment 320 IB 1501229 F ...
Page 352: ...321 IB 1501229 F 6 Spindle Adjustment ...
Page 404: ...373 IB 1501229 F 7 Troubleshooting ...
Page 455: ...MDS E EH Series Instruction Manual 7 Troubleshooting 424 IB 1501229 F ...
Page 456: ...425 IB 1501229 F 8 Maintenance ...
Page 475: ...MDS E EH Series Instruction Manual 8 Maintenance 444 IB 1501229 F ...
Page 476: ...445 IB 1501229 F 9 Power Backup System ...
Page 494: ...463 IB 1501229 F 10 Appx 1 Cable and Connector Assembly ...
Page 504: ...473 IB 1501229 F 11 Appx 2 D A Output Specifications for Drive Unit ...
Page 514: ...483 IB 1501229 F 12 Appx 3 Protection Function ...
Page 523: ...MDS E EH Series Instruction Manual 12 Appx 3 Protection Function 492 IB 1501229 F ...
Page 524: ...493 IB 1501229 F 13 Appx 4 Compliance to EC Directives ...
Page 528: ...497 IB 1501229 F 14 Appx 5 EMC Installation Guidelines ...
Page 540: ...509 IB 1501229 F 15 Appx 6 Higher Harmonic Suppression Measure Guidelines ...
Page 550: ......
Page 554: ......