MDS-E/EH Series Instruction Manual
4 Setup
155
IB-1501229-F
Select the servo functions.
A function is assigned to each bit.
Set this in hexadecimal format.
bit F : h2c HAS control cancel amount
0: 1/4 (standard) 1: 1/2
Related parameters: SV034/bit1
bit E :
Not used. Set to "0".
bit D : oru Overrun detection width unit
0: mm (normal setting) 1:
μ
m
bit C : odu Excessive error detection width unit
0: mm (normal setting) 1:
μ
m
bit B : ilm2u Current limit value (SV014) in special control setting unit
0: Stall current % (normal setting) 1: Stall current 0.01%
bit A-1 :
Not used. Set to "0".
bit 0 : irms Motor current display
0: Motor q axis current display (normal) 1: Motor effective current display
Set the machine system's spring constant when selecting lost motion compensation type 3.
When not using, set to "0".
Related parameters: SV016, SV041, SV082/bit2,1, SV086
---Setting range---
0 to 32767 (0.01%/
μ
m)
Set the machine system's viscous coefficient when selecting lost motion compensation type 3.
When not using, set to "0".
Related parameters: SV016, SV041, SV082/bit2,1, SV086
---Setting range---
0 to 32767 (0.01%•s/mm)
Set the vibration frequency to suppress when machine vibration occurs.
(Normally, do not set 80 or less.)
Set to "0" when not using.
Related parameters: SV083/bit3-1, SV115
---Setting range---
0 to 5000 (Hz)
#2284
SV084 SSF7
Servo function 7
#2285
SV085 LMCk
Lost motion compensation 3 spring constant
#2286
SV086 LMCc
Lost motion compensation 3 viscous coefficient
#2287
SV087 FHz4
Notch filter frequency 4
irms
h2c
ilm2u
odu
oru
Summary of Contents for MDS-E
Page 1: ......
Page 3: ......
Page 15: ......
Page 17: ......
Page 19: ......
Page 21: ......
Page 31: ......
Page 32: ...1 IB 1501229 F 1 Installation ...
Page 76: ...45 IB 1501229 F 2 Wiring and Connection ...
Page 132: ...101 IB 1501229 F 3 Safety Function ...
Page 142: ...111 IB 1501229 F 4 Setup ...
Page 277: ...MDS E EH Series Instruction Manual 4 Setup 246 IB 1501229 F ...
Page 278: ...247 IB 1501229 F 5 Servo Adjustment ...
Page 351: ...MDS E EH Series Instruction Manual 5 Servo Adjustment 320 IB 1501229 F ...
Page 352: ...321 IB 1501229 F 6 Spindle Adjustment ...
Page 404: ...373 IB 1501229 F 7 Troubleshooting ...
Page 455: ...MDS E EH Series Instruction Manual 7 Troubleshooting 424 IB 1501229 F ...
Page 456: ...425 IB 1501229 F 8 Maintenance ...
Page 475: ...MDS E EH Series Instruction Manual 8 Maintenance 444 IB 1501229 F ...
Page 476: ...445 IB 1501229 F 9 Power Backup System ...
Page 494: ...463 IB 1501229 F 10 Appx 1 Cable and Connector Assembly ...
Page 504: ...473 IB 1501229 F 11 Appx 2 D A Output Specifications for Drive Unit ...
Page 514: ...483 IB 1501229 F 12 Appx 3 Protection Function ...
Page 523: ...MDS E EH Series Instruction Manual 12 Appx 3 Protection Function 492 IB 1501229 F ...
Page 524: ...493 IB 1501229 F 13 Appx 4 Compliance to EC Directives ...
Page 528: ...497 IB 1501229 F 14 Appx 5 EMC Installation Guidelines ...
Page 540: ...509 IB 1501229 F 15 Appx 6 Higher Harmonic Suppression Measure Guidelines ...
Page 550: ......
Page 554: ......