Set the magnification of the excitation current stabilizing gain. (For Mitsubishi adjustment)
When set to "0", the excitation current stabilization is disabled.
When not using, set to "0".
---Setting range---
0 to 32767
Not used. Set to "0".
Not used. Set to "0".
Not used. Set to "0".
In the magnetic pole position detection function, the command motor speed and motor speed during the po-
sition command stop are monitored.
Set the command motor speed level and motor speed level during the position command stop in "r/min" unit.
When the command motor speed level is set to "0", the magnetic pole position error is detected at 10r/min.
Set to "10" as a standard setting when the magnetic pole position error detection function is enabled.
This detects the magnetic pole position error when the motor speed is "100r/min".
Ten-thousands digit, Thousands digit ------------ Command motor speed level (10r/min)
Hundreds digit, Tens digit, Ones digit ----------- Motor speed level (10r/min)
---Setting range---
0 to 31999
Set the magnification against delay/lead compensation (SP006) of the high-response acceleration/deceler-
ation (valid when SP226/ bitD is set to "1").
Normally, set to "0". Set this parameter to suppress overshooting when the speed is reached.
---Setting range---
0 to 10000 (0.01%)
When the spindle slows down due to multiple cutting, set the processable speed as percentage against the
NC command speed.
When "0" is set, the magnification is the same as when "85" is set. When set to "-1", the allowable width will
be disabled.
---Setting range---
-1,0 to 100(%)
When setting the machine side encoder resolution in pulse (p) unit, set the number of pulses to four bite data
of SP097 (high-order) and SP019 (low-order) in pulse (p) unit.
When SP097=0, the setting unit of SP019 is (kp).
Refer to SP019 for details.
Related parameters: SP019, SP020, SP098
---Setting range---
-1 to 32767
#13090
SP090 TMKD
Spindle output stabilizing gain D axis
#13091
SP091
#13092
SP092
#13093
SP093
#13094
SP094 MPV
Magnetic pole error detection speed
#13095
SP095 VIAX
Lead compensation scale during high-response accel-
eration/deceleration
#13096
SP096 SDW
Speed slowdown allowable width
#13097
SP097 RNG1ex
Extension sub side encoder resolution
Summary of Contents for MDS-E
Page 1: ......
Page 3: ......
Page 15: ......
Page 17: ......
Page 19: ......
Page 21: ......
Page 31: ......
Page 32: ...1 IB 1501229 F 1 Installation ...
Page 76: ...45 IB 1501229 F 2 Wiring and Connection ...
Page 132: ...101 IB 1501229 F 3 Safety Function ...
Page 142: ...111 IB 1501229 F 4 Setup ...
Page 277: ...MDS E EH Series Instruction Manual 4 Setup 246 IB 1501229 F ...
Page 278: ...247 IB 1501229 F 5 Servo Adjustment ...
Page 351: ...MDS E EH Series Instruction Manual 5 Servo Adjustment 320 IB 1501229 F ...
Page 352: ...321 IB 1501229 F 6 Spindle Adjustment ...
Page 404: ...373 IB 1501229 F 7 Troubleshooting ...
Page 455: ...MDS E EH Series Instruction Manual 7 Troubleshooting 424 IB 1501229 F ...
Page 456: ...425 IB 1501229 F 8 Maintenance ...
Page 475: ...MDS E EH Series Instruction Manual 8 Maintenance 444 IB 1501229 F ...
Page 476: ...445 IB 1501229 F 9 Power Backup System ...
Page 494: ...463 IB 1501229 F 10 Appx 1 Cable and Connector Assembly ...
Page 504: ...473 IB 1501229 F 11 Appx 2 D A Output Specifications for Drive Unit ...
Page 514: ...483 IB 1501229 F 12 Appx 3 Protection Function ...
Page 523: ...MDS E EH Series Instruction Manual 12 Appx 3 Protection Function 492 IB 1501229 F ...
Page 524: ...493 IB 1501229 F 13 Appx 4 Compliance to EC Directives ...
Page 528: ...497 IB 1501229 F 14 Appx 5 EMC Installation Guidelines ...
Page 540: ...509 IB 1501229 F 15 Appx 6 Higher Harmonic Suppression Measure Guidelines ...
Page 550: ......
Page 554: ......