(2) Adjusting the cutting feed
To adjust the cutting rate, the NC axis specification parameter clamp speed (clamp) and acceleration/deceleration
time constant (G1t*) are adjusted. The in-position width at this time must be set to the same value as actual cutting.
• Determining the clamp rate and adjusting the acceleration/deceleration time constant
(Features)The maximum cutting rate (clamp speed) can be determined freely.
(Adjustment)Carry out cutting feed reciprocation operation with dwell at the maximum cutting rate and adjust the
acceleration/deceleration time constant so that the maximum current command value during
acceleration/deceleration is within the range shown below.
• Setting the step acceleration/deceleration and adjusting the clamp speed
(Features)The acceleration/deceleration time constant is determined with the position loop in the servo, so the
acceleration/deceleration F
Δ
T can be reduced.
(Adjustment)Set 1 (step) for the acceleration/deceleration time constant and carry out cutting feed reciprocation
operation with dwell. Adjust the cutting feed rate so that the maximum current command value during
acceleration/deceleration is within the range shown below, and then set the value in the clamp speed.
Maximum tolerable current command value when adjusting the cutting feed acceleration/deceleration time constant
MDS-E Series (200V)
MDS-EH Series (400V)
Motor
model
Max. current
command value
Motor
model
Max. current
command value
Motor
model
Max. current
command value
HG46
Within 266%
HG-H75
Within 245%
HQ-H903
Within 175%
HG56
Within 273%
HG-H105
Within 189%
HQ-H1103
Within 147%
HG96
Within 182%
HG-H54
Within 294%
HG75
Within 245%
HG-H104
Within 245%
HG105
Within 189%
HG-H154
Within 266%
HG54
Within 294%
HG-H204
Within 217%
HG104
Within 245%
HG-H354
Within 231%
HG154
Within 266%
HG-H453
Within 175%
HG224
Within 217%
HG-H703
Within 168%
HG204
Within 217%
HG-H903
Within 203%
HG354
Within 294%
HG-H1502
Within 133%
HG123
Within 133%
HG223
Within 161%
HG303
Within 168%
HG453
Within 205%
HG703
Within 168%
HG903
Within 203%
HG142
Within 133%
HG302
Within 147%
CAUTION
Always set the same value for the cutting feed time constant between the interpolation axes.
Summary of Contents for MDS-E
Page 1: ......
Page 3: ......
Page 15: ......
Page 17: ......
Page 19: ......
Page 21: ......
Page 31: ......
Page 32: ...1 IB 1501229 F 1 Installation ...
Page 76: ...45 IB 1501229 F 2 Wiring and Connection ...
Page 132: ...101 IB 1501229 F 3 Safety Function ...
Page 142: ...111 IB 1501229 F 4 Setup ...
Page 277: ...MDS E EH Series Instruction Manual 4 Setup 246 IB 1501229 F ...
Page 278: ...247 IB 1501229 F 5 Servo Adjustment ...
Page 351: ...MDS E EH Series Instruction Manual 5 Servo Adjustment 320 IB 1501229 F ...
Page 352: ...321 IB 1501229 F 6 Spindle Adjustment ...
Page 404: ...373 IB 1501229 F 7 Troubleshooting ...
Page 455: ...MDS E EH Series Instruction Manual 7 Troubleshooting 424 IB 1501229 F ...
Page 456: ...425 IB 1501229 F 8 Maintenance ...
Page 475: ...MDS E EH Series Instruction Manual 8 Maintenance 444 IB 1501229 F ...
Page 476: ...445 IB 1501229 F 9 Power Backup System ...
Page 494: ...463 IB 1501229 F 10 Appx 1 Cable and Connector Assembly ...
Page 504: ...473 IB 1501229 F 11 Appx 2 D A Output Specifications for Drive Unit ...
Page 514: ...483 IB 1501229 F 12 Appx 3 Protection Function ...
Page 523: ...MDS E EH Series Instruction Manual 12 Appx 3 Protection Function 492 IB 1501229 F ...
Page 524: ...493 IB 1501229 F 13 Appx 4 Compliance to EC Directives ...
Page 528: ...497 IB 1501229 F 14 Appx 5 EMC Installation Guidelines ...
Page 540: ...509 IB 1501229 F 15 Appx 6 Higher Harmonic Suppression Measure Guidelines ...
Page 550: ......
Page 554: ......