MDS-E/EH Series Instruction Manual
5 Servo Adjustment
271
IB-1501229-F
【
#2315
】
SV115 SSF10 Servo function 10
bit F : are Notch filter5 all frequencies adopted
When enabled, Notch filter5 all frequencies adoptive range is not limited regardless of SV115/bit4,5
setting.
0: Disable 1: Enable
bit E-C: dsl Notch filter frequency display
Switch the "AFLT frequency" display on drive monitor screen to check every notch filter frequency.
When the selected notch filter is not used, "0" is displayed.
bitE,D,C=
000 : Estimated resonance frequency (Normal display)
001 : Notch filter 1 frequency
010 : Notch filter 2 frequency
011 : Notch filter 3 frequency (always displays 1125Hz)
100 : Notch filter 4 frequency
101 : Notch filter 5 frequency
Other settings: setting prohibited
bit B : ade5 Notch filter 5 / Adoptive follow-up function
0: Disable 1: Enable
bit A : ade4 Notch filter 4 / Adoptive follow-up function
0: Disable 1: Enable
bit 9 : ade2 Notch filter 2 / Adoptive follow-up function
0: Disable 1: Enable
bit 8 : ade1 Notch filter 1 / Adoptive follow-up function
0: Disable 1: Enable
bit 7-6 : dsn Estimated resonance frequency display holding time
Set the estimated resonance frequency display holding time to the "AFLT frequency" display on
drive monitor screen.
bit7,6=
00: 4 [s]
01: 8 [s]
10: 12 [s]
11: 16 [s]
bit 5-4 : dfhz Notch filter frequency range
Set the adaptive range of the notch filter frequency. When the adaptive follow-up function is enabled
and if the estimated resonance frequency exists in the set range, the notch filter will be adapted.
Normally set this parameter to "00".
bit5,4=
00: -10 to 10 [%]
01: -20 to 20 [%]
10: -30 to 30 [%]
11: -40 to 40 [%]
bit 3-0 : esn Sensitivity of estimated resonance frequency
Set the sensitivity of the estimated resonance frequency. Smaller setting value enables to detect
smaller vibration component, however, adoptive movement will be repeated frequently. Normally set
this parameter to "0".
0 : Normal setting (same sensitivity as A) 1 : Sensitivity high to F : Sensitivity low
Summary of Contents for MDS-E
Page 1: ......
Page 3: ......
Page 15: ......
Page 17: ......
Page 19: ......
Page 21: ......
Page 31: ......
Page 32: ...1 IB 1501229 F 1 Installation ...
Page 76: ...45 IB 1501229 F 2 Wiring and Connection ...
Page 132: ...101 IB 1501229 F 3 Safety Function ...
Page 142: ...111 IB 1501229 F 4 Setup ...
Page 277: ...MDS E EH Series Instruction Manual 4 Setup 246 IB 1501229 F ...
Page 278: ...247 IB 1501229 F 5 Servo Adjustment ...
Page 351: ...MDS E EH Series Instruction Manual 5 Servo Adjustment 320 IB 1501229 F ...
Page 352: ...321 IB 1501229 F 6 Spindle Adjustment ...
Page 404: ...373 IB 1501229 F 7 Troubleshooting ...
Page 455: ...MDS E EH Series Instruction Manual 7 Troubleshooting 424 IB 1501229 F ...
Page 456: ...425 IB 1501229 F 8 Maintenance ...
Page 475: ...MDS E EH Series Instruction Manual 8 Maintenance 444 IB 1501229 F ...
Page 476: ...445 IB 1501229 F 9 Power Backup System ...
Page 494: ...463 IB 1501229 F 10 Appx 1 Cable and Connector Assembly ...
Page 504: ...473 IB 1501229 F 11 Appx 2 D A Output Specifications for Drive Unit ...
Page 514: ...483 IB 1501229 F 12 Appx 3 Protection Function ...
Page 523: ...MDS E EH Series Instruction Manual 12 Appx 3 Protection Function 492 IB 1501229 F ...
Page 524: ...493 IB 1501229 F 13 Appx 4 Compliance to EC Directives ...
Page 528: ...497 IB 1501229 F 14 Appx 5 EMC Installation Guidelines ...
Page 540: ...509 IB 1501229 F 15 Appx 6 Higher Harmonic Suppression Measure Guidelines ...
Page 550: ......
Page 554: ......