MDS-E/EH Series Instruction Manual
5 Servo Adjustment
296
IB-1501229-F
Measure the roundness and read the torsion amounts generated when the direction is reversed (linear
parts in the following figure). Set the smaller value of the read values to the parameter: SV206 (unit:
0.01
μ
m) as the compensation amount.
Example: When the values are +X = 4.5
μ
m, -X = 4.2
μ
m, +Y = 3.9
μ
m, and -Y = 4.2
μ
m,
set SV206 for X axis to 420 and for Y axis to 390.
(3) Perform lost motion adjustment.
After setting the torsion amount (SV206), perform the lost motion adjustment (automatic) with NC
Analyzer2 adjustment function.
If requiring to improve the accuracy further than the adjustment result, adjust the lost motion
compensation amount.
Check the result in roundness measurement after adjusting the compensation amount.
【
#2406
】
SV206 FCTC Full-closed torsion compensation control torsion amount
Set the compensation amount of full-closed torsion compensation function.
Set the torsion amount between the motor-end position and the machine-end position right after the
stop as a standard setting value.
When not using, set to "0".
---Setting range---
0 to 32767 (0.01
μ
m)
【
#2316
】
SV116 SSF11 Servo function 11
bit 1 : fctcfw
Full-closed torsion compensation function forward direction
compensation enabled
Compensate the torsion amount in the forward direction with the full-closed torsion compensation
function. When compensating the torsion amount in the reverse direction only, set to "0".
0: Stop 1: Start
Motor-end roundness measurement
Summary of Contents for MDS-E
Page 1: ......
Page 3: ......
Page 15: ......
Page 17: ......
Page 19: ......
Page 21: ......
Page 31: ......
Page 32: ...1 IB 1501229 F 1 Installation ...
Page 76: ...45 IB 1501229 F 2 Wiring and Connection ...
Page 132: ...101 IB 1501229 F 3 Safety Function ...
Page 142: ...111 IB 1501229 F 4 Setup ...
Page 277: ...MDS E EH Series Instruction Manual 4 Setup 246 IB 1501229 F ...
Page 278: ...247 IB 1501229 F 5 Servo Adjustment ...
Page 351: ...MDS E EH Series Instruction Manual 5 Servo Adjustment 320 IB 1501229 F ...
Page 352: ...321 IB 1501229 F 6 Spindle Adjustment ...
Page 404: ...373 IB 1501229 F 7 Troubleshooting ...
Page 455: ...MDS E EH Series Instruction Manual 7 Troubleshooting 424 IB 1501229 F ...
Page 456: ...425 IB 1501229 F 8 Maintenance ...
Page 475: ...MDS E EH Series Instruction Manual 8 Maintenance 444 IB 1501229 F ...
Page 476: ...445 IB 1501229 F 9 Power Backup System ...
Page 494: ...463 IB 1501229 F 10 Appx 1 Cable and Connector Assembly ...
Page 504: ...473 IB 1501229 F 11 Appx 2 D A Output Specifications for Drive Unit ...
Page 514: ...483 IB 1501229 F 12 Appx 3 Protection Function ...
Page 523: ...MDS E EH Series Instruction Manual 12 Appx 3 Protection Function 492 IB 1501229 F ...
Page 524: ...493 IB 1501229 F 13 Appx 4 Compliance to EC Directives ...
Page 528: ...497 IB 1501229 F 14 Appx 5 EMC Installation Guidelines ...
Page 540: ...509 IB 1501229 F 15 Appx 6 Higher Harmonic Suppression Measure Guidelines ...
Page 550: ......
Page 554: ......