MDS-E/EH Series Instruction Manual
6 Spindle Adjustment
332
IB-1501229-F
(b) Adjusting deceleration time
Adjusts deceleration time in the same manner as acceleration time by using SP071 (variable current limit
during deceleration, lower limit value) and SP072 (variable current limit during deceleration, break point
speed).
CH1
CH2
Adjust deceleration time
Deceleration time
adjustment completed
Set SP071 and SP072
When SP071=100 is set, current limit during deceleration is
constant regardless of the speed. When setting SP071 to
100 or less and SP072 to maximum rotation speed or less,
deceleration time will be longer as current limit during
deceleration may be variable depending on the speed.
* Although a value more than 100 can be set to SP071,
basically, 100 or less should be set.
Acceleration/deceleration
operation
Execute M5 stop operation from the maximum rotation speed.
Set the "Time-series data
measurement" with NC Analyzer
as shown on the right
Get
Waveform type
< NC Analyzer setting (Time-series data measurement) >
Speed feedback (r/min)
Current feedback
Deceleration time
Speed feedback
Current feedback
Summary of Contents for MDS-E
Page 1: ......
Page 3: ......
Page 15: ......
Page 17: ......
Page 19: ......
Page 21: ......
Page 31: ......
Page 32: ...1 IB 1501229 F 1 Installation ...
Page 76: ...45 IB 1501229 F 2 Wiring and Connection ...
Page 132: ...101 IB 1501229 F 3 Safety Function ...
Page 142: ...111 IB 1501229 F 4 Setup ...
Page 277: ...MDS E EH Series Instruction Manual 4 Setup 246 IB 1501229 F ...
Page 278: ...247 IB 1501229 F 5 Servo Adjustment ...
Page 351: ...MDS E EH Series Instruction Manual 5 Servo Adjustment 320 IB 1501229 F ...
Page 352: ...321 IB 1501229 F 6 Spindle Adjustment ...
Page 404: ...373 IB 1501229 F 7 Troubleshooting ...
Page 455: ...MDS E EH Series Instruction Manual 7 Troubleshooting 424 IB 1501229 F ...
Page 456: ...425 IB 1501229 F 8 Maintenance ...
Page 475: ...MDS E EH Series Instruction Manual 8 Maintenance 444 IB 1501229 F ...
Page 476: ...445 IB 1501229 F 9 Power Backup System ...
Page 494: ...463 IB 1501229 F 10 Appx 1 Cable and Connector Assembly ...
Page 504: ...473 IB 1501229 F 11 Appx 2 D A Output Specifications for Drive Unit ...
Page 514: ...483 IB 1501229 F 12 Appx 3 Protection Function ...
Page 523: ...MDS E EH Series Instruction Manual 12 Appx 3 Protection Function 492 IB 1501229 F ...
Page 524: ...493 IB 1501229 F 13 Appx 4 Compliance to EC Directives ...
Page 528: ...497 IB 1501229 F 14 Appx 5 EMC Installation Guidelines ...
Page 540: ...509 IB 1501229 F 15 Appx 6 Higher Harmonic Suppression Measure Guidelines ...
Page 550: ......
Page 554: ......